Ricoh D649 Field Service Manual page 108

Table of Contents

Advertisement

4. Service Tables
Maximum allowable carrier drop during
image data reception
Bit 1
0
0-1
0
1
1
Select cancellation of high-speed RX if
carrier signal lost while receiving
2
0: Off
1: On
3
Not used
Maximum allowable frame interval during
image data reception.
4
0: 5 s 1: 13 s
5
Not used
Reconstruction time for the first line in
receive mode
6
0: 6 s 1: 12 s
7
Not used
G3 Switch 0B Not used (do not change the settings).
G3 Switch 0C Not used (do not change the settings).
106
Bit 0
Value (ms)
0
200
1
400
0
800
1
Not used
These bits set the acceptable modem carrier
drop time.
Try a longer setting if error code 0-22 is
frequent.
This switch setting determines if high-speed
receiving ends if the carrier signal is lost when
receiving during non-ECM mode
Do not change the settings
This bit set the maximum interval between EOL
(end-of-line) signals and the maximum interval
between ECM frames from the other end.
Try using a longer setting if error code 0-21 is
frequent.
Do not change the settings.
When the sending terminal is controlled by a
computer, there may be a delay in receiving
page data after the local machine accepts set-
up data and sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set
this bit to 1 to give the sending machine more
time to send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line
should come within 5 s of CFR.
Do not change the settings.