Electro-pneumatic Control Panel Display Screens
Feedback Control
Control Screen
Feedback
Feedback
Control
To reduce the risk of injury due to electric shock, remove power to the control panel before
entering the control panel to make connections for measurement devices.
Selecting scale feedback
Description
Icon/Field
Icon/Field
Icon/Field
Description
Description
Feedback
Feedback
Feedback Type
Type
Type
Select feedback type:
• None: No feedback enabled.
• Pulse Meter (Volume): A pulse meter measuring volume dispensed must be
• Pulse Meter (Mass): A pulse meter measuring mass dispensed must be
• Scale (Positive): A scale measuring weight is connected; weight is increasing as
• Scale (Negative): A scale measuring weight is connected; weight is decreasing
K K K - - - Factor*
Factor*
Factor*
This field appears if a pulse meter type input is selected. Set the unit value a
single pulse represents.
20 mA
mA Mass**
Mass**
20
20
mA
Mass**
This field appears if a scale type input is selected. Set the weight associated with
the 20 mA signal input in this field.
56
Triplex Sales
1-847-839-8442
www.triplexsales.com
Screen
Screen
connected to CM8281–12 (20 kHz max) to use this feedback type.
connected to CM8281–12 (20 kHz max) to use this feedback type.
material is dispensed.
as material is dispensed. This input is used if the STU system is mounted on
a scale.
Selecting pulse feedback