Electro-pneumatic Control Panel Display Screens
Outputs
Outputs
Outputs from
from
from the
the Allen
the
Allen
Allen- - - Bradley
Variable
Variable
Variable Name
Name
Name
AB2BR_rec_airAssistPres-
sure_psi
AB2BR_rec_primeTime_s
AB2BR_rec_emptyTime_s
AB2BR_rec_sealDeflateTime_s
AB2BR_rec_airAssistTime_s
AB2BR_rec_batchAmount-
Mass_lbs
AB2BR_rec_batchAmountVol-
ume_gal
AB2BR_batchEnabled
AB2BR_networkOverwriteBit-
field
62
Triplex Sales
1-847-839-8442
www.triplexsales.com
Bradley Controller
Bradley
Controller
Controller
Data Type
Data
Data
Type Possible
Type
Possible
Possible
Values
Values
Values
REAL
REAL
INT
INT
INT
INT
INT
INT
INT
INT
REAL
REAL
REAL
REAL
BOOL
TRUE, FALSE
DINT
Bitfield
Notes
Notes
Notes
Corresponds to bit 9 in the
AB2BR_networkOverwriteBitfield
variable. Units in psi.
Corresponds to bit 10 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
Corresponds to bit 11 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
Corresponds to bit 12 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
Corresponds to bit 13 in the
AB2BR_networkOverwriteBitfield
variable. Units in seconds.
Corresponds to bit 14 in the
AB2BR_networkOverwriteBitfield
variable. If batching is enabled, the
evacuation will halt when the amount
of material pumped matches this
value. Units in pounds.
Corresponds to bit 15 in the
AB2BR_networkOverwriteBitfield
variable. If batching is enabled, the
evacuation will halt when the amount
of material pumped matches this
value. Units in gallons.
Corresponds to bit 16 in the
AB2BR_networkOverwriteBitfield
variable. This switches between
an "Auto" sequence and a "Batch"
sequence.
This variable is used as a bitfield,
where every denoted output variable
has a corresponding bit. If the remote
PLC intends the STU to read the
value in from the Ethernet/IP network
interface and make it active in the
system, the corresponding bit for
that variable must be set to TRUE
in this bitfield. When a bit is set to
TRUE, any value changes from the
STU's touchscreen (including loading
a new recipe) will be overwritten by
the network value, unless "Override
Remote" is checked on the STU
Network screen. When a bit is FALSE,
the STU system ignores the network
value.