D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call Graco Technical Assis- tance at 1–800–543–0339.
Page 3
WARNING WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 4. D If there is any static sparking or you feel an electric shock while using this equipment, stop spraying immediately.
Installation Typical Installation Air Requirements At 500 rpm and 20 psi (1.4 bar), the agitator air motor requires 22 cfm (0.65 m /min.) of air. Air consumption air line lubricator increases as the speed and air pressure is increased. agitator motor See the graph on page 8.
Operation Operating the Agitator Cleaning the Shaft Open and adjust the ball valve (1) until the motor is Each week, clean any dried fluid from around the bear- running at the lowest speed needed to thoroughly agi- ing (10) and motor support (19) area of the shaft (18). tate the fluid.
NOTE: If the air motor still doesn’t operate properly, D Do not use kerosene or other combustible contact a Graco distributor. Do not try to repair the air solvents. motor yourself. D Eye protection is required.
Parts Model 225883 Carbon Steel Agitator for 55 gallon drum Ref. Part No. Description Qty. 208393 BALL VALVE; See 307068 for service 203399 SCREW, clamp 100003 SCREW, hex hd cap; 3/8-16 x 1-1/2” 100017 SCREW, hex hd cap; 1/2-13 x 1-1/2” 100053 SCREW, soc hd set;...
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.