Graco SaniForce STU Operation page 63

Hide thumbs Also See for SaniForce STU:
Table of Contents

Advertisement

Inputs to to to the
the Allen
Allen- - - Bradley
Bradley Controller
Inputs
Inputs
the
Allen
Bradley
Variable Name
Variable
Variable
Name
Name
BR2AB_systemState
BR2AB_containerLow
BR2AB_containerEmpty
BR2AB_sealInflated
BR2AB_systemLoaded
BR2AB_batchSequenceCom-
plete
BR2AB_autoSequenceComplete
BR2AB_currentJobNumber
BR2AB_ramPosition_in
BR2AB_jobAmountMass_lbs
BR2AB_jobAmountVolume_gal
BR2AB_scaleReading_lbs
BR2AB_evnt_eventTimestamp
BR2AB_evnt_eventGroup
BR2AB_evnt_eventIndex
BR2AB_evnt_acknowledge
BR2AB_networkInterlock
3A5416L
Triplex Sales
1-847-839-8442
www.triplexsales.com
Electro-pneumatic Control Panel Display Screens
Controller
Controller
Data Type
Data
Data
Type
Type Possible
Possible
Possible
Values
Values
Values
DINT
0 (Sys Busy),
1 (Standby),
2 (Manual
Run), 3
(Auto Run)
BOOL
TRUE, FALSE N/A
TRUE, FALSE N/A
BOOL
BOOL
TRUE, FALSE N/A
BOOL
TRUE, FALSE N/A
BOOL
TRUE, FALSE This will only be set if batch
BOOL
TRUE, FALSE This will be set when an Auto
DINT
DINT
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
DINT
DINT
SINT
0 (Alarm), 1
(Deviation),
2 (Advisory)
SINT
SINT
BOOL
TRUE, FALSE N/A
BOOL
TRUE, FALSE N/A
Notes
Notes
Notes
N/A
target has been achieved. If
the batching sequence ends
by emptying the container, the
"BR2AB_autoSequenceComplete"
variable will be set instead.
sequence completes, or a Batch
sequence empties a container before
reaching the target batch amount.
N/A
Identifies the distance from the laser
position sensor to the top beam or
plate of the system. Units are inches.
Amount of material pumped in the
current job if a "Mass" type feedback
is selected in system settings.
Otherwise, this variable has a value of
-1. Units in pounds.
Amount of material pumped in
the current job if a "Volume" type
feedback is selected in system
settings. Otherwise, this variable has
a value of -1. Units in gallons.
Identifies the current value of a scale
if a scale is connected and configured
in the system. Units in pounds.
Timestamp in Unix time.
Has a value of 255 if no events need
acknowledgment. See Event Table.
Has a value of 255 if no events need
acknowledgment. See Event Table.
63

Advertisement

Table of Contents
loading