Carrier Omnizone 50BVC Installation, Start-Up, Service And Controls Operation And Troubleshooting page 30

Water-cooled indoor self-contained systems
Table of Contents

Advertisement

Table 13 — Electrical Data — with Belt Drive Motor, Inverter Duty* (50BVV,W,T)
RATED
MODELS
VOLTAGE
208-230/3/60
208-230/3/60
208-230/3/60
208-230/3/60
460/3/60
460/3/60
034
460/3/60
460/3/60
575/3/60
575/3/60
575/3/60
575/3/60
208-230/3/60
208-230/3/60
208-230/3/60
208-230/3/60
460/3/60
460/3/60
044
460/3/60
460/3/60
575/3/60
575/3/60
575/3/60
575/3/60
208-230/3/60
208-230/3/60
208-230/3/60
208-230/3/60
460/3/60
460/3/60
054
460/3/60
460/3/60
575/3/60
575/3/60
575/3/60
575/3/60
208-230/3/60
208-230/3/60
208-230/3/60
208-230/3/60
460/3/60
460/3/60
064
460/3/60
460/3/60
575/3/60
575/3/60
575/3/60
575/3/60
LEGEND
FLA
— Full Load Amps
HP
— Horsepower
LRA
— Locked Rotor Amps
RLA
— Rated Load Amps
COMPRESSOR
VOLTAGE
RLA
MIN/MAX
QTY
(EACH)
197/253
2
55.8
197/253
2
55.8
197/253
2
55.8
197/253
2
55.8
414/506
2
26.9
414/506
2
26.9
414/506
2
26.9
414/506
2
26.9
518/632
2
23.7
518/632
2
23.7
518/632
2
23.7
518/632
2
23.7
197/253
4
33.3
197/253
4
33.3
197/253
4
33.3
197/253
4
33.3
414/506
4
17.9
414/506
4
17.9
414/506
4
17.9
414/506
4
17.9
518/632
4
12.8
518/632
4
12.8
518/632
4
12.8
518/632
4
12.8
197/253
4
48.1
197/253
4
48.1
197/253
4
48.1
197/253
4
48.1
414/506
4
18.6
414/506
4
18.6
414/506
4
18.6
414/506
4
18.6
518/632
4
14.7
518/632
4
14.7
518/632
4
14.7
518/632
4
14.7
197/253
4
55.8
197/253
4
55.8
197/253
4
55.8
197/253
4
55.8
414/506
4
26.9
414/506
4
26.9
414/506
4
26.9
414/506
4
26.9
518/632
4
23.7
518/632
4
23.7
518/632
4
23.7
518/632
4
23.7
INDOOR FAN MOTOR
LRA
MOTOR
MOTOR
(EACH)
HP
QTY
340
7.5
1
340
10
1
340
15
1
340
20
1
173
7.5
1
173
10
1
173
15
1
173
20
1
132
7.5
1
132
10
1
132
15
1
132
20
1
239
7.5
2
239
10
2
239
15
2
239
20
2
125
7.5
2
125
10
2
125
15
2
125
20
2
80
7.5
2
80
10
2
80
15
2
80
20
2
245
7.5
2
245
10
2
245
15
2
245
20
2
125
7.5
2
125
10
2
125
15
2
125
20
2
100
7.5
2
100
10
2
100
15
2
100
20
2
340
7.5
2
340
10
2
340
15
2
340
20
2
173
7.5
2
173
10.0
2
173
15.0
2
173
20.0
2
132
7.5
2
132
10.0
2
132
15.0
2
132
20.0
2
NOTE: The presence of an inverter duty motor does not guarantee that
the unit will be provided with a VFD, only 50BVW (VAV) units are pro-
vided with a VFD as standard.
30
POWER SUPPLY
MIN
MAX
FLA
CIRCUIT
FUSE/
(EACH)
AMPS
HACR
19.4
145.0
200
25.2
150.8
200
37.8
163.4
200
49.0
174.6
225
9.7
70.2
90
12.6
73.1
100
18.9
79.4
100
24.5
85.0
110
7.5
60.8
80
10.3
63.6
80
15.1
68.4
90
19.6
72.9
90
19.4
180.3
200
25.2
191.9
225
37.8
218.3
250
49.0
243.5
250
9.7
95.5
110
12.6
101.3
110
18.9
114.1
125
24.5
126.7
150
7.5
69.4
80
10.3
75.0
80
15.1
85.2
100
19.6
95.3
110
19.4
243.2
250
25.2
254.8
300
37.8
280.0
300
49.0
302.7
350
9.7
98.5
110
12.6
104.3
110
18.9
116.9
125
24.5
129.5
150
7.5
77.5
90
10.3
83.1
90
15.1
92.8
100
19.6
102.9
110
19.4
276.0
300
25.2
287.6
300
37.8
312.8
350
49.0
335.2
350
9.7
133.7
150
12.6
139.5
150
18.9
152.1
175
24.5
163.3
175
7.5
115.7
125
10.3
121.3
125
15.1
130.9
150
19.6
139.9
150

Advertisement