6.
Remove hardware retaining support bushings to auger
housing. See Figure 50.
7.
Remove auger assembly from housing. See
Figure 51.
Figure 50
Figure 51
See Figure 52.
IMPORTANT: Flange bushing remains inside support
bushing.
8.
Remove support bushing from auger shaft end.
9.
Remove shear bolt from auger shaft.
10. Remove auger. Use of penetrating oil or heat may be
necessary to remove auger.
IMPORTANT: If rust is present on auger shaft, remove with
sand paper and wipe clean with oil.