Table 3-1 Controller Configuration Variables - Carrier 69NT40-511-1 Operating And Service Manual

Container refrigeration unit
Hide thumbs Also See for 69NT40-511-1:
Table of Contents

Advertisement

CONFIGURATION
NUMBER
1
Bypass Valve Enable
2
Evaporator Fan Speed
3
Number of Sensor Probes
4
Dehumidification Mode
5
Probe Calibration
6
Condenser Fan Speed Select
7
Unit Selection, 20FT/ 40FT/45FT
8
Single Phase/Three Phase Motor
9
Refrigerant Selection
10
Compressor Speed
11
Defrost "Off" Selection
12
TXV/Solenoid Quench Valve
13
Unloader
14
Condenser Pressure Control (CPC)
15
Discharge Temperature Sensor
16
DataCORDER Option
17
Discharge Pressure Sensor
18
Heater
19
Controlled Atmosphere
20
Pressure Sensor (Suction)
21
Auto-Transformer
22
Economy Mode Option
23
Defrost Interval Timer Save Option
24
Advanced Pre-Trip Enhanced Test
25
Pre-Trip Test Points/Results Recording
26
Heat Lockout
27
Suction Temperature Display
28
Bulb Mode
29
Arctic Mode
30
Compressor Size
31
Probe Check Logic
32
Single Evaporator Fan Option
33
Snap Freeze Option
34
Degree Celsius Lockout Option
35
Humidification Mode
36
Modulation Valve Type
37
Electronic Partlow
38
Quench Bypass Valve
39
Current Limit Range
40
Demand Defrost
Table 3-1. Controller Configuration Variables
TITLE
3-3
DEFAULT
OPTION
In
Out
dS (Dual)
SS (Single)
FoUR
dUAL
On
Off
noCal
CAL
Off (Single)
On (Variable)
40ft
20ft,45
1Ph
3Ph
r134a
r12, r22, bLEnd
Out (Single)
In (Dual)
noOFF
OFF
Out (TXV)
In (Solenoid)
Out
In
In
Out
Out
In
On (Yes)
Off (No)
Out (No)
In (Yes)
Old (Low Watt)
nEW (High Watt)
Out (No)
In (Yes)
Out (No)
In (Yes)
Std
--
Off
Std, Full
noSAV
SAV
Off
On
rSLts
data
Set to --10_C
Set to--5_C
Out
In
Nor
bulb
Out
In
41 CFM
37 CFM
Std
SPEC
2EF0
1EF0
Off
SnAP
bOth
_F
Off
On
1
2, 3
rEtur
SuPPL, bOth
Out
In
Out
In
Out
In
T-268-07