Table 3-4 Controller Configuration Variables - Carrier 69NT40-511-300 Operation And Service

Container refrigeration units
Table of Contents

Advertisement

"AA##," if the alarm is active, where ## is the alarm
number. "IA##," will show if the alarm is inactive
d. "END" is displayed to indicate the end of the alarm list
if any alarms are active. "CLEAr" is displayed if all the
alarms in the list are inactive.
e. If no alarms are active, the Alarm Queue may be
cleared. The exception to this rule is the DataCORD-
ER Alarm Queue Full alarm (AL91) , which does not
have to be inactive in order to clear the alarm list. To
Clear the Alarm List:
CONFIGURATION
NUMBER
CnF01
CnF02
CnF03
CnF04
CnF05
CnF06
CnF07
CnF08
CnF09
CnF10
CnF11
CnF12
CnF13
CnF14
CnF15
CnF16
CnF17
CnF18
CnF19
CnF20
CnF21
CnF22
CnF23
CnF24
CnF25
CnF26
CnF27
CnF28
CnF29
CnF30
CnF31
CnF32
CnF33
CnF34
CnF35
CnF36
CnF37
CnF38
CnF39
T-285

Table 3-4 Controller Configuration Variables

TITLE
Bypass Valve Enable
Evaporator Fan Speed
Control Sensors
Dehumidification Mode
Reserved for future use
Condenser Fan Speed Select
Unit Selection, 20FT/ 40FT/45FT
Single Phase/Three Phase Motor
Refrigerant Selection
Two Speed Compressor Logic
Defrost "Off" Selection
TXV/Solenoid Quench Valve
Unloader
Condenser Pressure Control (CPC)
Discharge Temperature Sensor
DataCORDER Present
Discharge Pressure Sensor
Heater
Controlled Atmosphere
Suction Pressure Sensor
Autotransformer
Economy Mode Option
Defrost Interval Timer Save Option
Advanced Pre-Trip Enhanced Test Series Option
Pre-Trip Test Points/Results Recording Option
Heat Lockout Change Option
Suction Temperature Display Option
Bulb Mode Option
Arctic Mode
Compressor Size
Probe Check Option
Single Evaporator Fan Option
Snap Freeze Option
Degree Celsius Lockout Option
Humidification Mode
SMV Type
Electronic Temperature Recorder
Quench Bypass Valve
Expanded Current Limit Range
1. Press the ALT. MODE & ALARM LIST keys.
2. Press the UP/DOWN ARROW key until "CLEAr" is
displayed.
3. Press the ENTER key. The alarm list will clear and
"-- -- -- -- -- " will be displayed.
4. Press the ALARM LIST key. "AL" will show on the left
display and "-- -- -- -- -- " on the right display when
there are no alarms in the list.
5. Upon clearing of the Alarm Queue, the Alarm light will
be turned off.
DEFAULT
In
dS (Dual)
FOUr
On
----------
OFF (Single)
40ft
1Ph
r134a
Out (Single)
noOFF
Out (TXV)
Out
In
Out
On (Yes)
Out (No)
Old (Low Watt)
Out (No)
Out (No)
Out
OFF
noSAv
Auto
rSLtS
Set to --10_C
Out
NOr
Out
41 CFM
Std
2EF0
OFF
bOth
OFF
1 (standard)
rEtUR
Out
Out
3-12
OPTION
Out
SS (Single)
duAL
OFF
n/a
On (Variable)
20ft,45
3Ph
r12, r22, bLEnd
In (Dual)
OFF
In (Solenoid)
In
Out
In
OFF (No)
In (Yes)
nEW (High Watt)
In (Yes)
In (Yes)
In
Std, Full
SAv
Auto2, Auto 3
dAtA
Set to --5_C
In
bULb
In
37 CFM
SPEC
1EF0
SnAP
_F
On
2, 3 (stepper)
SUPPL, bOth
In
In

Advertisement

Table of Contents
loading

Table of Contents