(5) 3-Phase Residual Current Circuit Breaker (3P RCCB)
1-Phase Residual Current Circuit Breaker (1P RCCB)
3P RCCB
< Note >
 Do not use this breaker as the ON/OFF switch to the load
(6) Battery Isolator
OFF position
(7) Throttle Switch

5-3. Voltage Regulator

(1) Voltage Regulator
1P RCCB
When turning the switch to OFF, the engine
electric circuit does not activate due to no
battery power.
ON position
The switch is to change engine speed (revolution). Turn the switch to
[IDLING] when engine start, warm-up or cool-down, and turn to [RUN] when
using the equipment at the rated speed (50Hz).
The dial adjusts generator output voltage.
By turning the dial clockwise, you can increase the voltage.
By turning the dial counter-clockwise, you can decrease the voltage.
Each receptacle, 3-Phase and 1-Phase is
incorporated with RCCB respectively.
When current leak occurs, it trips to stop
power transmission to load.