7-2. Connecting Load Cable

WARNING : Electric Shock
Before connecting or disconnecting a load cable from output receptacles,
always turn a circuit breaker to OFF position, stop the engine, and turn the
Power Switch to the OFF position.
CAUTION : Fire
 Do not connect AC output to any indoor wiring.
< Note >
 Divide loads into 3 circuits proportionally as possible, when using the maximum
output power especially, and connect them to each phase (R,S,T) respectively.
 Be careful to limit the current under the rated current per the phase.
 Note that the 1-phase output power decreases when 3-phase output power is
used simultaneously.
 Be careful to limit the total current under the rated output current when
using 1-Phase and 3-Phase output simultaneously.