8-6. Checking Battery
CAUTION : Injuries to eyes and skin
Battery fluid contains diluted sulfuric acid. Avoid contact with eyes, skin
or on clothing. If the acid comes in contact, especially with eyes,
flush with a lot of water, and contact physician or doctor immediately.
CAUTION : Explosion
When the liquid level is below the LOWER level, never use the equipment
nor recharge battery.
Battery may emit some combustible gas, so keep it away from fire and
sparks.
Check the fluid level. If the level is near or lower than the LOWER LEVEL, add
1
distilled water until the fluid level reaches the UPPER LEVEL limit.
Make sure that the battery cables are firmly secured to the posts. Tighten the clamps
2
more if necessary.
< Note >
Check the hydrometer of the battery fluid. If it falls below 1.23, the battery requires
recharging. Please call our authorized distributor or our engineering section.
■Replacing the Battery
Remove the clamp and cable from negative (-)
1
post from the battery (always remove negative
side first).
2
Remove the battery fixing clamp.
3
Remove the cable from positive (+).
4
Remove the battery from the seat.
※Reinstall a new Battery in the reverse order (always install the cable to the positive (+) post of
the new Battery first).
+Post
-Post
Fixing Clamp
26