Checking Coolant / Water - Shindaiwa DGA12DM Owner's And Operator's Manual

Diesel engine generator
Table of Contents

Advertisement

 Viscosity and temperature
Tem
p
-30
(C)
(2) Replacing Engine Oil Volume

8-2. Checking Coolant / Water

WARNING : Injuries
Before performing any equipment check or maintenance, stop the engine,
and turn the Power Switch to the OFF position.
CAUTION : Burns
Do not open the radiator cap while operating this equipment or
immediately after stopping the equipment, to avoid sustaining burns from
hot vapor or water.
Do not touch the engine and muffler during operation and immediately
after stopping the equipment, for the temperature can reach extremely
high levels.
Check the radiator and coolant reservoir tank for water and add water in case of
shortage.
(1) Checking Radiator / Adding water
Remove the radiator plate and open the
1
radiator cap cover.
2
Remove the radiator cap.
3
Fill up water to the radiator water inlet top.
Reinstall the cap and tighten it.
4
Close the radiator cap cover and reinstall the radiator plate.
5
SAE20/20W
SAE10W
SAE30
-15
0
SAE10W-30
SAE15W-40/20W-40
Lubrication Oil (including the oil in filter)
7.3 (0.3)
Value in ( ) shows the oil in filter
SAE40
15
25
30
(Unit: Liter)
Radiator Cap
22
Radiator Plate
Radiator Cap Cover
Inlet

Advertisement