Other System Menu Items - Furuno FSV-30 Installation Manual

Color scanning sonar
Hide thumbs Also See for FSV-30:
Table of Contents

Advertisement

3.4 Other SYSTEM Menu Items

This section mainly shows you how to set up according to external equipment connected.
Default settings are underlined.
3.4.1 INTERFACE SETTING menu
NMEA 1 BAUD RATE
Set the transmission rate for the NMEA 1 port.
(4800 bps, 9600 bps, 19200 bps, 38400 bps)
NMEA 2 BAUD RATE
Set the transmission rate for the NMEA 2 port.
(4800 bps, 9600 bps, 19200 bps, 38400 bps)
CIF BAUD RATE
Set the transmission rate for the CIF port. If the CS-120A is connected, choose "2400 bps".
(2400 bps, 4800 bps, 9600 bps, 19200 bps)
AUX BAUD RATE
Set the transmission rate for the AUX port. (2400 bps, 4800 bps, 9600 bps, 19200 bps)
EXT KP INPUT
Set the input logic of KP from an external equipment. (DISABLE, POSITIVE, NEGATIVE)
DISABLE: No use external KP.
POSITIVE: Synchronize with leading edge of input pulse.
NEGATIVE: Synchronize with trailing edge of input pulse
Note: To transmit with external KP, set the TX INTERNAL to "0" in the H-SCAN SETTING
menu.
EXT KP OUTPUT
Choose the KP output logic, POSITIVE or NEGATIVE. (POSITIVE, NEGATIVE)
MENU
INTERFACE SETTING
NMEA 1 BAUD RATE : 4800 bps
NMEA 2 BAUD RATE : 4800 bps
CIF BAUD RATE
: 4800 bps
AUX BAUD RATE
: 19200 bps
EXT KP INPUT
: DISABLE
: NEGATIVE
EXT KP OUTPUT
INTERFACE SETTING menu
QUIT
QUIT