Installing The Attachment Flange (Option) - Furuno FSV-30 Installation Manual

Color scanning sonar
Hide thumbs Also See for FSV-30:
Table of Contents

Advertisement

1.6 Installing the Attachment Flange (option)

The attachment flange permits use of the tank for the CSH-20 series using the 1200 mm
stroke transducer.
Attachment flange Type: OP10-27, Code no: 000-067-050)
Name
Attachment flange
O-ring
Hex. nut
Flat washer
Spring washer
Procedure
1. Clean the hull unit flange, O-ring and O-ring groove. Coat them with a slight amount of
grease.
2. Use 48 hex. nuts, flat washers and spring washers to fasten the attachment flange to
retraction tank.
3. Place the O-ring in position on the attachment flange.
To install the attachment flange and the hull unit, see paragraph 1.1.4.
Attachment flange for 1200 mm stroke transducer, sectional view
Type
10-077-5802
CO 0318A (V585)
M20 SUS304
M20 SUS304
M20 SUS304
Code No.
100-303-610
000-166-370-10
000-863-116
000-864-136
000-864-270
Hex. Bolt
Flat Washer
Hull Unit Flange
O-ring
Flat Washer
Spring Washer
Hex. Nut
Attachment Flange
O-ring
Existing Tank
Flat Washer
Spring Washer
Hex. Nut
Qty
Remarks
1
1
48
24
24
1-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fsv-30s

Table of Contents