Other SYSTEM Menu Items

This section shows you how to set up external equipment. Default settings are
underlined.
3.4.1
INTERFACE SETTING menu
NMEA 1 BAUD RATE
Set the transmission rate for the NMEA 1 port.
(2400 bps, 4800 bps, 9600 bps, 19200 bps)
NMEA 2 BAUD RATE
Set the transmission rate for the NMEA 2 port.
(2400 bps, 4800 bps, 9600 bps, 19200 bps)
CIF BAUD RATE
Set the transmission rate for the CIF port. (2400 bps, 4800 bps, 9600 bps, 19200
bps) If the CS-120A is connected, select "2400 bps".
AUX BAUD RATE
Set the transmission rate for the AUX port. (2400 bps, 4800 bps, 9600 bps,
19200 bps)
EXT KP INPUT
Select whether the KP signal from external equipment is used or not, and set the
edge polarity. (DISABLE, POSITIVE, NEGATIVE)
Note: Set TX INTERVAL in H-SCAN SETTING menu to "0" for transmission with
external kp signal.
EXT KP OUTPUT
Select the KP output logic, POSITIVE or NEGATIVE. (POSITIVE, NEGATIVE)
3-8
MENU
INTERFACE SETTING
NMEA 1 BAUD RATE : 4800 bps
NMEA 2 BAUD RATE : 4800 bps
CIF BAUD RATE
: 4800 bps
AUX BAUD RATE
: 19200 bps
: DISABLE
EXT KP INPUT
EXT KP OUTPUT