PLOTTER-RELATED ALARMS
9.1 Arrival/Anchor Watch
Alarm
The arrival alarm informs you that your boat
is approaching a destination waypoint. The
area that defines an arrival zone is that of a
circle which you approach from the outside
of the circle. The alarm will be released if your
boat enters the circle. The anchor watch
alarm sounds to warn you that your boat is
moving when it should be at rest.
When the arrival or anchor watch alarm is
violated, the audible alarm sounds and the
alarm icon
and the indication ARR or
ANCHR appear. You may silence the alarm
with the CLR key. The indication remains on
the screen until the cause of the alarm is cor-
rected.
Own ship
position
Arrival alarm
Range
set
Anchor watch alarm
Figure 9-1 How the arrival and
anchor watch alarms work
The arrival and anchor watch alarms cannot
be activated together. You may activate one
as follows:
1. Press the MENU key.
Destination
waypoint
: Alarm range
Own ship
position
Destination
waypoint
: Alarm range
2. Press the [5] key to select ALARM
SETUP.
ALARM SETUP
ARRIVAL
ARRIVAL
Range
XTE
ON
Range
SPEED
WITHIN
Speed
TEMP
WITHIN
Temp
TRIP
ON
Range
: Cursor
Figure 9-2 Alarm setup menu
3. Press
to select ARRIVAL.
4. Press s or t to select ARRIVAL or AN-
CHOR.
5. Press
to send the cursor to the second
line (Range).
6. Key in the alarm range desired. The avail-
able range is 00.001 to 99.999 miles.
7. Press the ENT key.
8. Press the MENU key.
When a destination is set and the arrival alarm
is activated a red dashed circle circumscribes
the destination waypoint and it denotes arrival
alarm range.
Figure 9-3 Arrival alarm range
1/2
OFF
ANCHOR
00.500nm
OFF
00.250nm
OFF
OVER
11.0~15.0kt
OVER
OFF
+11.0~+15.0 C
OFF
0005.00nm
ESC: Esc
0
Arrival alarm
range
Destination