Typical Wiring Schematic, 30Rap018-030 Units — Power Wiring - Carrier AQUASNAP AIR COOLED CHILLERS WITH COMFORTLINK CONTROLS 30RAP010-060 Operation And Service Manual

Air-cooled chillers with comfortlink controls
Hide thumbs Also See for AQUASNAP AIR COOLED CHILLERS WITH COMFORTLINK CONTROLS 30RAP010-060:
Table of Contents

Advertisement

STANDARD
OPTIONAL
TERMINAL
DISCONNECT
BLOCK
CB1A
TB1A
11
1
12
2
13
3
EQUIP GND
FU5
FU6
BLK
RED
1
1
HF
H4
H3
H2
~
H1
TRAN3
SECONDARY
115V
WHT
WHT
X3
X1
FU4
GRN/YEL
XF
GFI-CO
2
BLK
FIOP/ACCESSORY
2
LINE
BRASS SCREW
BRASS SCREW
SILVER SCREW
SILVER SCREW
RESET
VOLTAGE
SERIES
TEST
575-3-60
100
230-3-60
400,500
GRN-YEL
208-3-60
500
LOAD
460-3-60
600
REPLACE
FUSE
TRAN
UNIT VOLTAGE
WITH
NUMBER
SIZE
208/230-3-60
FNQ-R-3.5
380-3-60
FNQ-R-2.5
FU1 & FU2
200VA
460-3-60
FNQ-R-2
575-3-60
FNQ-R-1.5
380-3-60,460-3-60,575-3-60
FU3 (24V)
200VA
FNM-10
208/230-3-60
460-3-60,575-3-60
FNQ-R-2.5
F
U
5
&
F
U
6
5
0
0
V
A
208/230-3-60,230-3-60
FNQ-R-3.5
380-3-60,460-3-60,575-3-60
FU4 (115V)
500VA
FNM-6
208/230-3-60
FB1
380-3-60,460-3-60,575-3-60
NONE
LP-CC-20
(NO MM)
208/230-3-60
KTK-R-15
FB1
380-3-60,460-3-60,575-3-60
NONE
(WITH MM)
208/230-3-60
KTK-R-20
380-3-60,460-3-60,575-3-60
FB2
NONE
LP-CC-20
208/230-3-60
380-3-60,460-3-60,575-3-60
FB3
NONE
LP-CC-20
208/230-3-60
TABLE 1
TERMINAL
VOLTAGE
SERIES
CONNECTIONS
FOR PRIMARY SIDE
575-3-60
100
H1 & H2
380-3-60
200
H1 & H2
230-3-60
500
H2 & H4
208-3-60
500
H3 & H4
460-3-60
600
H1 & H4
FU1
BLK
FU2
YEL
CONNECT FOR
APPROPRIATE
PRIMARY VOLTAGE
SEE TABLE 1
TRAN1
PRIMARY
H3
H1
H2
H4
TB4
SECONDARY 24V
7
RED
XF
FU3
X1
X2
GRN/YEL
RED
A1
BRN
SW2
C1
C TB1
BRN
B1
UPC FIOP
VIO
24VAC
CB3
3.2 AMPS
UPC
BRN
2
GND
TB4
VIO
6
VIO
1
HOT
VIO
J1
3
3
3
3
2
2
MBB
2
BRN
2
BRN
1
1
VIO
1
1
RED
J2
BRN
1
3
VIO
BRN
CWFS
BLU
BRN
Fig. 6A — Typical Wiring Schematic, 30RAP018-030 Units — Power Wiring
BLK
21
BLK
BLK
YEL
22
YEL
YEL
YEL
BLK
BLU
BLU
23
BLU
BLU
TERMINAL
TERMINAL
CONNECTIONS
CONNECTIONS FOR
BLK
FOR PRIMARY SIDE
SECONDARY SIDE
H1-H2
XF-X2
YEL
H2-H4
XF-X2
H3-H4
XF-X2
H1-H4
XF-X2
BLU
YEL
BLK
BLU
BLK
YEL
BLU
NOTES:
1. FACTORY WIRING IS IN ACCORDANCE WITH UL 1995 STANDARDS.
3. ALL FIELD INTERLOCK CONTACTS MUST HAVE A MIN RATING OF
4. COMPRESSOR AND FAN MOTORS ARE THERMALLY PROTECTED--
5. TERMINALS 13 & 14 OF LVT ARE FOR FIELD CONNECTION
6. FOR 500 SERIES UNIT OPERATION AT 208-3-60V LINE VOLTAGE,
7. FOR UNITS WITH LOW AMBIENT MOTOR MASTER V FIOP/ACCESSORY,
TB4
TB1
5
C
RED
BRN
J1
3
3
3
3
EXV
2
2
2
BRN
2
1
1
RED
1
J2
1
FIOP/ACCESSORY
DGS FIOP
J1
3
3
3
3
2
2
AUX
2
EMM
2
2
BRN
12
1
1
1
J2
1
11
1
RED
J1
24
380V,460V,575V
CCB-1
ONLY
CSB-A1
BLK
BLK
11
21
YEL
YEL
12
22
BLU
BLU
13
23
YEL
BLU BLK
CCB-2
CSB-A2
BLK
11
21
BLK
YEL
12
22
YEL
BLU
13
23
BLU
208/230V ONLY
CHILLED WATER PUMP FIOP
MS-CWP1
CWP1
BLK
L1
T1
L1
T1
YEL
L2
T2
L2
T2
BLU
L3
T3
L3
T3
MS-CWP2
CWP2
BLK
L1
T1
L1
T1
YEL
L2
T2
L2
T2
BLU
L3
T3
L3
T3
FB3
FB1
FC1
BLK
11
21
BLK
11
21
11
YEL
12
22
YEL
12
22
12
BLU
13
23
BLU
13
23
13
FC2
HIGH SCCR
BLK
11
ONLY
YEL
12
BLU
13
BLK
YEL
LOW AMBIENT OPERATION (MOTORMASTER V)
FB3
FB1
MM-A
BLK
BLK
L1
11
21
11
21
YEL
L2
12
22
12
22
YEL
BLU
L3
13
23
13
23
BLU
HIGH SCCR
ONLY
FB2
FC2
BLK
BLK
11
21
11
YEL
YEL
12
22
12
BLU
BLU
13
13
23
BLK
YEL
ANY FIELD MODIFICATIONS OR ADDITIONS MUST BE IN
COMPLIANCE WITH ALL APPLICABLE CODES.
C MIN WIRE FOR FIELD POWER SUPPLY.
2 AMPS @ 24VAC SEALED. SEE FIELD INTERLOCK WIRING.
THREE PHASE MOTORS PROTECTED AGAINST PRIMARY SINGLE
PHASE CONDITIONS.
OF REMOTE ON-OFF. THE CONTACT MUST BE RATED FOR DRY
CIRCUIT APPLICATION CAPABLE OF HANDLING A 5VDC
1 MA TO 20 MA LOAD.
TRAN1 PRIMARY CONNECTIONS MUST BE MOVED TO TERMINALS H3
FAN CONTACTOR FC1 IS REPLACED WITH MOTORMASTER RELAY MMR.
CH-A1
BLU
BLK
CA1
1
BLK
T1
11
21
2
YEL
T2
COMP A1
12
22
3
BLU
T3
13
23
GRN/YEL
CH-A2
BLU
BLK
CA2
1
BLK
T1
11
21
2
COMP A2
YEL
12
22
T2
3
BLU
T3
13
23
GRN/YEL
BLK
L1
CWP1
WATER
L2
BLK
PUMP
BLK
L3
GRN/YEL
L1
BLK
CWP2
WATER
BLK
L2
PUMP
BLK
L3
GRN/YEL
1
BLK-1
21
2
OFM1
22
BLK-2
3
BLK-3
23
GRN/YEL
1
21
BLK-1
2
OFM2
22
BLK-2
3
23
BLK-3
GRN/YEL
CHC
1
4
2
BLK
BLK
1
WHT
BLK
3
2
COOLER/PUMP
COOLER/PUMP
HEATERS
HEATERS
(380,460,575V)
(208/230,230V)
CHC
2
8
6
BLK
WHT
3
FIOP/ACCESSORY
1
T1
BLK-1
2
T2
OFM1
BLK-2
3
T3
BLK-3
GRN/YEL
YEL
2
MMR
* MM SIGNAL CONNECTION
VIO
11
14
*1
T
B
VOLTAGE
H
Z
240
1/4W
1
208/230/460/575
6
0
25
RED
FROM
1
3
A
380
6
0
AUX-J4
2
BLK
1
21
BLK-1
2
BLK-2
OFM2
22
3
23
BLK-3
GRN/YEL
CHC
1
4
2
BLK
BLK
1
WHT
BLK
3
2
COOLER/PUMP
COOLER/PUMP
HEATERS
HEATERS
(380,460,575V)
(208/230,230V)
CHC
2
8
6
BLK
WHT
3
8. IF CHILLED WATER PUMP INTERLOCK IS USED,
REMOVE JUMPER FROM TERMINAL 11 TO 17 AND
WIRE INTERLOCK CONTACT ACROSS TERMINALS 11 & 17.
9. MP-A1 NOT USED IN THE FOLLOWING UNITS:
018,020: ALL UNITS
025,030: 460V UNITS WITHOUT DIGITAL SCROLL
10. MP-A2 NOT USED IN THE FOLLOWING UNITS:
018-020: ALL UNITS
025,030: 460V UNITS
11. JUMPER PLUG REQUIRED WHEN MP NOT USED
& H4.
a30-4965