Carrier AQUASNAP AIR COOLED CHILLERS WITH COMFORTLINK CONTROLS 30RAP010-060 Operation And Service Manual page 94

Air-cooled chillers with comfortlink controls
Hide thumbs Also See for AQUASNAP AIR COOLED CHILLERS WITH COMFORTLINK CONTROLS 30RAP010-060:
Table of Contents

Advertisement

CCN CONFIGURATION TABLES — DUALCHIL (Dual Chiller Configuration Settings)
DESCRIPTION
LEAD/LAG
Lead/Lag Chiller Enable
Master/Slave Select
Slave Address
Lead/Lag Balance Select
Lead/Lag Balance Delta
Lag Start Delay
Parallel Configuration
CCN CONFIGURATION TABLES — DISPLAY (Marquee Display SETUP)
DESCRIPTION
Service Password
Password Enable
Metric Display
Language Selection
CCN CONFIGURATION TABLES — EXVACONF (EXV Circuit A Configuration)
DESCRIPTION
EXV Circ. A Start Pos
EXV Circ. A Min Position
EXVA Steps in Range
EXVA Steps Per Second
EXVA Fail Position in %
EXVA Minimum Steps
EXVA Maximum Steps
EXVA Overrun Steps
EXVA Stepper Type
High SCT Threshold
Open EXV X% on 2nd Comp
Open EXV X% on DISCRSOL
Pre-Open EXV - Fan Adding
Pre-Close EXV - Fan Sub
Pre-Close EXV - Lag Shut
Lag Start Delay
CCN CONFIGURATION TABLES — EXVBCONF (EXV Circuit B Configuration)
DESCRIPTION
EXV Circ. B Start Pos
EXV Circ. B Min Position
EXVB Steps in Range
EXVB Steps Per Second
EXVB Fail Position in %
EXVB Minimum Steps
EXVB Maximum Steps
EXVB Overrun Steps
EXVB Stepper Type
CCN CONFIGURATION TABLES — MM_CONF (Motormaster Configuration)
DESCRIPTION
Motormaster Select
Head Pressure P Gain
Head Pressure I Gain
Head Pressure D Gain
Minimum Fan Speed
APPENDIX B — CCN TABLES (cont)
VALUE
Enable/Dsable
Master/Slave
0 to 239
0 = None
40 to 400
0 to 30
Yes
VALUE
nnnn
Enable/Disable
Off/On
0 = ENGLISH
1 = FRANCAIS
2 = ESPANOL
3 = PORTUGUES
VALUE
nnn.n
nnn.n
nnnnn
nnnnn
nnnn.nn
nnnnn
nnnnn
nnnnn
nnn
nnn.n
nnn.n
nnn.n
nnn.n
nnn.n
nnn.n
nnn
VALUE
nnn.n
nnn.n
nnnnn
nnnnn
nnnn.nn
nnnnn
nnnnn
nnnnn
nnn
VALUE
No/Yes
nnn.n
nnn.n
nnn.n
nnn.n
DEFAULT
Dsable
Master
2
0
168
5
Yes
DEFAULT
1111
Enable
Off
0
DEFAULT
50.0
8.0
1596/2500
200
0
0
1596/2500
167
Bipolar
115
10
5
10
10
10
10
DEFAULT
50.0
8.0
1596/2500
200
0
0
1596/2500
167
Bipolar
DEFAULT
No
1.0
0.1
0.0
5.0
94
UNITS
POINT NAME
LL_ENA
MS_SEL
SLV_ADDR
LL_BAL
hours
LL_BAL_D
minutes
LL_DELAY
PARALLEL
UNITS
POINT NAME
PASSWORD
PASS_EBL
DISPUNIT
LANGUAGE
UNITS
POINT NAME
%
EXVASTRT
%
EXVAMINP
steps
EVXARANG
steps
EXVARATE
%
EXVAPOSF
steps
EXVAMINS
steps
EXVAMAXS
steps
EXVAOVRS
EXVATYPE
°F
HIGH_SCT
%
EXV_HSCT
%
EXVDISCR
%
EXV_AFAN
%
EXV_MFAN
%
EXV_SLAG
secs
DELAYLAG
UNITS
POINT NAME
%
EXVBSTRT
%
EXVBMINP
steps
EVXBRANG
steps
EXVBRATE
%
EXVBPOSF
steps
EXVBMINS
steps
EXVBMAXS
steps
EXVBOVRS
EXVBTYPE
UNITS
POINT NAME
MM_SLCT
HP_PGAIN
HP_IGAIN
HP_DGAIN
%
MIN_VHP