Installing the Device
2.7 Installing the Mounting Brackets
2.7

Installing the Mounting Brackets

1.
Position one of the mounting brackets on one side of the RUGGEDCOM MX5000.
1
2
Figure 2.9
2.
Secure the mounting bracket with 20 flat head hex socket screws. Hand tighten
each screw and make sure each screw head is flush with the surface of the
mounting bracket.
3.
Repeat
RUGGEDCOM MX5000.
2.8

Installing the EMI Gaskets

The material for the EMI (Electro-Magnetic Interference) gaskets is provided in two
lengths for the two different sizes of patch panel openings in the RUGGEDCOM
MX5000:
To install the EMI gaskets, do the following:
1.
Make sure the groove surrounding each panel opening is free of dust, dirt or
liquid.
18
Mounting Bracket
#10-32×1/2" Flat Head Hex Socket Screw
Mounting Brackets
Step 1
and
Step 2
for the mounting bracket on the opposite side of the
EMI Gasket Material Length
19.5"
35.5"
Patch Panel Opening
D, E, F and G
A, B, C, H, J and K
RUGGEDCOM MX5000RE