Siemens SIMATIC NET SCALANCE M826 Operating Instructions Manual

Hide thumbs Also See for SIMATIC NET SCALANCE M826:

Advertisement

Quick Links

SIMATIC NET
Industrial Remote
Communication Remote Networks
SCALANCE M826
Operating Instructions
10/2022
C79000-G8976-C362-07
Preface
Safety notices
Security recommendations
Description of the device
Installation and removal
Connecting up
Maintenance and cleaning
Technical specifications
Dimension drawings
Approvals
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SCALANCE M826

  • Page 1 Preface Safety notices Security recommendations SIMATIC NET Description of the device Industrial Remote Communication Remote Networks Installation and removal SCALANCE M826 Connecting up Operating Instructions Maintenance and cleaning Technical specifications Dimension drawings Approvals 10/2022 C79000-G8976-C362-07...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    SCALANCE M826-2 SHDSL router 6GK5826-2AB00-2AB2 You will find the article numbers for the Siemens products of relevance here in the following catalogs: • SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI • SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 •...
  • Page 4 (https:// support.industry.siemens.com/cs/ww/en/view/84922825) SIMATIC NET manuals You will find SIMATIC NET manuals on the Internet pages of Siemens Industry Online Support: • using the search function: Link to Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/) Enter the entry ID of the relevant manual as the search item.
  • Page 5 Feed under https://www.siemens.com/cert (https://www.siemens.com/cert). Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. The firmware is available on the Internet pages of the Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15982/dl):...
  • Page 6 Note the different national regulations. Device defective If a fault develops, send the device to your SIEMENS representative for repair. Repairs on-site are not possible. Trademarks The following and possibly other names not identified by the registered trademark sign ®...
  • Page 7: Table Of Contents

    Table of contents Preface ..............................3 Safety notices ............................9 Security recommendations........................11 Description of the device ........................19 Product characteristics ....................... 19 Device view ........................20 Scope of delivery ....................... 20 Accessories ........................21 3.4.1 PLUG ..........................22 3.4.2 Installation ........................
  • Page 8 Table of contents Maintenance and cleaning ........................57 Technical specifications ........................59 Dimension drawings ..........................63 Approvals ............................. 65 EC declaration of conformity ....................66 9.1.1 ATEX..........................66 9.1.2 EMC........................... 67 9.1.3 RoHS ..........................67 UK Declaration of Conformity..................... 68 9.2.1 The Equipment and Protective Systems Intended for use in Potentially Explosive Atmospheres Regulations 2016..................
  • Page 9: Safety Notices

    Safety notices CAUTION To prevent injury and damage, read the manual before using the device. Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation"...
  • Page 10 Safety notices SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 11: Security Recommendations

    • For data transmission via a non-secure network, use an encrypted VPN tunnel (IPsec, OpenVPN). • Check the user documentation of other Siemens products that are used together with the device for additional security recommendations. • Using remote logging, ensure that the system protocols are forwarded to a central logging server.
  • Page 12 • Verify certificates based on the fingerprint on the server and client side to prevent "man in the middle" attacks. Use a second, secure transmission path for this. • Before sending the device to Siemens for repair, replace the current certificates and keys with temporary disposable certificates and keys, which can be destroyed when the device is returned.
  • Page 13 Implementation Information Disclosure Vulnerability (for example, BEAST). • Ensure that the latest firmware version is installed, including all security-related patches. You can find the latest information on security patches for Siemens products at the Industrial Security (https://www.siemens.com/industrialsecurity) or ProductCERT Security Advisories (https://www.siemens.com/cert/en/cert-security-advisories.htm) website.
  • Page 14 Security recommendations • Use the authentication and encryption mechanisms of SNMPv3 if possible. Use strong passwords. • Configuration files can be downloaded from the device. Ensure that configuration files are adequately protected. Configuration files can be password protected during download. You enter passwords on the WBM page "System >...
  • Page 15 Security recommendations • If a secure alternative is available for a protocol, use it. The following protocols provide secure alternatives: – SNMPv1/v2 → SNMPv3 Check whether use of SNMPv1 is necessary. SNMPv1 is classified as non-secure. Use the option of preventing write access. The product provides you with suitable setting options. If SNMP is enabled, change the community names.
  • Page 16 UDP/1812 Closed Closed ✓ ✓ ✓ Optional UDP/1813 SFTP Server TCP/22 Outgoing only Outgoing on‐ ✓ ✓ ✓ ✓ Siemens Re‐ TCP/443 Outgoing only Outgoing on‐ ✓ Optional ✓ mote Serv‐ ice (cRSP/ SRS) SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 17 Security recommendations Service Protocol/ Default port status Configurable Authenti‐ Encryp‐ Port number cation tion Local access External ac‐ Port Serv‐ cess SINEMA RC HTTPS/443 Outgoing only Outgoing on‐ ✓ ✓ ✓ ✓ and TCP/UDP depending on the server configuration SMTP Client TCP/25 Outgoing only Outgoing on‐...
  • Page 18 Security recommendations The table includes the following columns: • Layer 2 service The Layer 2 services that the device supports. • Default status The default status of the service (open or closed). • Service configurable Indicates whether the service can be configured via WBM / CLI. Layer 2 service Default status Configurable...
  • Page 19: Description Of The Device

    Description of the device Product characteristics Interfaces Functionality SCALANCE M826-2 DSL interface Ethernet interface 4 x RJ45 10 / 100 Mbps Digital input/output Using the device in a PROFINET environment Note When using the device in a PROFINET environment, follow the configuration instructions in the configuration manuals: •...
  • Page 20: Device View

    Description of the device 3.3 Scope of delivery Device view On the device front: ① SHDSL connection ② Ethernet connectors (P1, P2, P3, P4) ③ SET button ④ Digital input (DI) ⑤ Digital output (DO) ⑥ Power supply connection ⑦ LED display On the device rear: ⑧...
  • Page 21: Accessories

    2. Check all the parts for transport damage. Accessories Technical data subject to change. You will find further information on the range of accessories in the Industry Mall (https:// mall.industry.siemens.com/mall/en/WW/Catalog/Products/10215915) Use the TIA Selection Tool (https://mall.industry.siemens.com/tst/) for configuring the device. SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 22: Plug

    Description of the device 3.4 Accessories 3.4.1 PLUG Type Properties Article number C-PLUG Removable data storage medium (256 MB) for the 6GK1900-0AB10 configuration data KEY-PLUG SINEMA RC Removable data storage medium (256 MB) to enable 6GK5908-0PB00 the connection functionality to SINEMA Remote Con‐ nect and for storing configuration data 3.4.2 Installation...
  • Page 23: Terminals

    Description of the device 3.5 Terminals Terminals Position The device has a 5-pin plug-in terminal block for the power supply and two 2-pin plug-in terminal blocks for the digital input and output. Connectors and terminal markings L1, M1, L2, M2 Input for the power supply Terminal block with five terminal con‐...
  • Page 24: Led Display

    Description of the device 3.6 LED display Terminals and wiring Connectors +DI, -DI /+D0, -DO L1, M1, L2, M2 28 AWG 16 AWG Wire end ferrule without plas‐ 0.2 mm 1.5 mm tic collar to DIN 46228/1 Wire end ferrule with plastic 0.2 mm 1.5 mm collar to DIN 46228/4...
  • Page 25 Description of the device 3.6 LED display Status Meaning No fault/error.   The device is starting up or an error has occurred. Flashing The bootloader waits in this state for a new firmware file that you can download using TFTP. Flashing Firmware on PLUG The device is performing a firmware update or downgrade.
  • Page 26: Set Button

    Description of the device 3.7 SET button Status Meaning Digital input inactive. Digital input active. Digital output inactive Digital output active. SET button Position The SET button is on the front of the device. SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 27: Plug

    Description of the device 3.8 PLUG Function The SET button has the following functions: • Restarting the device To restart the device, press the SET button briefly. Note If you make changes to the configuration and restart immediately afterwards with the SET button, the changes may be lost.
  • Page 28 Description of the device 3.8 PLUG The following PLUG types are available: • C-PLUG: The removable data storage medium only saves the configuration data of the device. • KEY-PLUG: In addition to the configuration data, the removable data storage medium contains a license with which specific functions can be enabled, e.g. SINEMA RC. •...
  • Page 29 – The configuration data of the device is stored in a secured memory area of the PLUG. This secured memory area can only be accessed via the authentication of the Siemens device. – The device checks whether or not a PLUG is inserted at one second intervals. If the device detects that the PLUG has been removed, it restarts automatically.
  • Page 30 Description of the device 3.8 PLUG SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 31: Installation And Removal

    Installation and removal Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. NOTICE Improper mounting Improper mounting may damage the device or impair its operation. • Before mounting the device, always ensure that there is no visible damage to the device. •...
  • Page 32 Installation and removal 4.1 Safety notices for installation Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Replacing components may impair suitability for Class 1, Division 2 or Zone 2. WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure.
  • Page 33 Installation and removal 4.1 Safety notices for installation WARNING Wall mounting is only permitted if the requirements for the housing, the installation regulations, the clearance and separating regulations for the control cabinets or housings are adhered to. The control cabinet cover or housing must be secured so that it can only be opened with a tool.
  • Page 34: Securing The Housing

    Installation and removal 4.3 Wall mounting Securing the housing Types of installation For the device, you have the following options: • Wall mounting (no ceiling mounting) • Installation on a DIN rail • Installation on the S7-300 mounting rail • Installation on the S7-1500 mounting rail •...
  • Page 35 Installation and removal 4.3 Wall mounting Installation 1. Prepare the drill holes for wall mounting. For the precise dimensions, refer to the section "Dimension drawings". 2. Secure the device to the wall with two screws. When mounting on a wall, use mounting fittings suitable for the type of wall.
  • Page 36: Installing On The Din Rail

    Installation and removal 4.4 Installing on the DIN rail Installing on the DIN rail Installation ① 1. Place the third housing guide of the device on the top edge of the DIN rail ② 2. Press the device down against the DIN rail until the spring catch locks in place 3.
  • Page 37: Installing On The S7-300 Standard Rail

    Installation and removal 4.5 Installing on the S7-300 standard rail Installing on the S7-300 standard rail Installation ① 1. Place the second housing guide of the device on the top edge of the standard rail ② 2. Press the device down against the standard rail until the spring catch locks in place 3.
  • Page 38: Installing On The S7-1500 Standard Rail

    Installation and removal 4.6 Installing on the S7-1500 standard rail Installing on the S7-1500 standard rail Installation ① 1. Place the first housing guide of the device on the top edge of the standard rail ② 2. Using a screwdriver, pull down the catch on the rear of the device.
  • Page 39: Mounting On A Pedestal

    Installation and removal 4.7 Mounting on a pedestal Mounting on a pedestal Installation ① 1. Place the third housing guide of the device on the top edge of the pedestal ② 2. Press the device down against the pedestal until the spring catch locks in place 3.
  • Page 40 Installation and removal 4.7 Mounting on a pedestal SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 41: Connecting Up

    Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. Note Strain relief for the Ethernet cables In order to avoid mechanical stress on the Ethernet cables and resulting interruption of the contact, fasten the cables at a short distance from the connector using a cable guide or busbar.
  • Page 42 Connecting up 5.1 Safety when connecting up Note Protective ground A PELV circuit contains a connection to protective ground. Without a connection to protective ground, or in case there is a fault in the connection to the protective ground, the voltage for the circuit is not stabilized.
  • Page 43 Connecting up 5.1 Safety when connecting up WARNING Lack of equipotential bonding If there is no equipotential bonding in hazardous areas, there is a risk of explosion due to equalizing current or ignition sparks. • Ensure that equipotential bonding is available for the device. WARNING Unprotected cable ends There is a risk of explosion due to unprotected cable ends in hazardous areas.
  • Page 44 Connecting up 5.1 Safety when connecting up WARNING Suitable cables at high ambient temperatures in hazardous area At an ambient temperature of ≥ 60 °C, use heat-resistant cables designed for an ambient temperature at least 20 °C higher. The cable entries used on the enclosure must comply with the IP degree of protection required by EN IEC / IEC 60079-0, GB 3836.1.
  • Page 45: Power Supply

    Connecting up 5.2 Power supply Power supply The power supply is connected using a 5-pin terminal block. The power supply is non-floating. Signal Description 24 VDC Ground Ground 24 VDC Functional ground, refer to the section "Grounding (Page 46)" You can find information on wiring in the section "Auto-Hotspot (Page 23)". SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 46: Grounding

    Connecting up 5.4 Digital input/output External power supply Note Permitted external power supplies The power supply unit to supply the SCALANCE M826 must comply with the requirements for a limited power source (LPS) according to IEC 62368-1. The external power supply for the SCALANCE M826 must meet the requirements for NEC class 2 circuits as specified in the National Electrical Code ®...
  • Page 47 Connecting up 5.4 Digital input/output Note Interference pulse To avoid evaluating an interference pulse, the pulse for the signal 1 (TRUE / HIGH) must be at least 200 ms. Rules for wiring • To wire the digital input/output, use a copper cable of category AWG18-16 or a cable with a cross-section of 0.75 to 1.5 mm •...
  • Page 48 Connecting up 5.4 Digital input/output Contact Assignment Input Ground If there is an adequate switching voltage at the digital input, the digital input is active and the "DI" LED is lit. The voltage applied to the "DI" contact is converted to a digital status by the device as follows: Voltage Status -30 to +3 V DC...
  • Page 49: Shdsl Connection

    Connecting up 5.5 SHDSL connection Contact Assignment Switching signal Relay 24 V DC / 1 A Ground The output is a switch that switches the signal at +DO to ‑DO. SHDSL connection CAUTION Risk of fire To reduce the risk of fire only use telephone cable with 26 AWG (0.125 mm ) or larger.
  • Page 50 Connecting up 5.5 SHDSL connection Distance [km] Max. possible data transmission rate [Mbps] Copper 2-wire cable with Copper 2-wire cable with a diameter of 0.6 mm a diameter of 1.4 mm 15.3 15.3 13.3 14.0 11.8 13.2 9.24 11.6 4.47 7.92 1.33 4.18 0.40...
  • Page 51 Connecting up 5.5 SHDSL connection Designated Port Root Port Alternate Port To allow data traffic via the ring, enable the "Spanning Tree" function in the WBM in "Layer 2 > Spanning Tree". Spanning tree prevents loops being formed in the network by allowing only one path and disabling the other (redundant) SHDSL interfaces for data traffic.
  • Page 52 Connecting up 5.5 SHDSL connection This parameter is used to calculate the path that will be selected. The path with the lowest value is selected as the path. The path costs of the port to port connection are calculated as follows: •...
  • Page 53: Ethernet Port

    Connecting up 5.6 Ethernet port The path costs to the root bridge are added from the port to port path costs from the bridge to the root bridge. Port role and port status The port role and port status are only negotiated when the SHDSL connection is actually established.
  • Page 54: Replacing The Plug

    Connecting up 5.7 Replacing the PLUG Replacing the PLUG NOTICE Do not remove or insert a C-PLUG / KEY-PLUG during operation! A PLUG may only be removed or inserted when the device is turned off. The device checks whether or not a PLUG is present at one second intervals. The device restarts if it is detected that the PLUG has been removed.
  • Page 55 Connecting up 5.7 Replacing the PLUG Removing the PLUG 1. Turn off the power to the device. 2. Insert a screwdriver between the front edge of the PLUG and the slot and release the PLUG. 3. Remove the PLUG. SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 56 Connecting up 5.7 Replacing the PLUG SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 57: Maintenance And Cleaning

    Maintenance and cleaning WARNING Unauthorized repair of devices in explosion-proof design Risk of explosion in hazardous areas • Repair work may only be performed by personnel authorized by Siemens. WARNING Impermissible accessories and spare parts Risk of explosion in hazardous areas •...
  • Page 58 Maintenance and cleaning SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 59: Technical Specifications

    Technical specifications   SCALANCE M826-2 Article number 6GK5 826-2AB00-2AB2 Ethernet interface Attachment to Industrial Ether‐ Quantity   Design RJ-45 jack   Characteristics: • 10/100BASE-T • Ethernet IEEE 802 • 10/100 Mbps WAN interface DSL connection Quantity   Design Terminal block, 2 terminals  ...
  • Page 60 Technical specifications   SCALANCE M826-2 Digital output Quantity Design Terminal block, 2 terminals Properties Rated voltage 24 VDC Safe Extra Low Volt‐ age (SELV) internally not current limited Maximum current carrying capacity 1 A Cables should be routed in pairs Maximum cable length <...
  • Page 61 Technical specifications   SCALANCE M826-2 Router functions • NAPT (port forwarding) • NAT (IP masquerading) • NAT traversal • 1:1 NAT • Dynamic DNS client • DNS cache • • Remote logging • Connection monitoring Configuration / management • Web-based administration user inter‐ face (WBM) •...
  • Page 62 Technical specifications SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 63: Dimension Drawings

    Dimension drawings Note CAx data You can find the CAx data on the Internet at (https://www.automation.siemens.com/bilddb/ index.aspx?lang=en) 1. Click on the "CAx data" link in the "Direct Links" area. The Industry Image Database page is loaded. 2. Enter the name or article number of the product in the search filter.
  • Page 64 Dimension drawings Figure 8-2 Side view SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 65: Approvals

    Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support at the following link: (https://support.industry.siemens.com/cs/ww/en/ps/...
  • Page 66: Ec Declaration Of Conformity

    Process Automation DE-76187 Karlsruhe Germany You can find the current EU declaration of conformity for these products on the Internet pages of Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15985/cert). The products described in these operating instructions meet the requirements of the following EC directives: •...
  • Page 67: Emc

    Approvals 9.1 EC declaration of conformity Applied standards: EN / EN IEC 60079-0 Hazardous areas - Part 0: Equipment - General requirements EN 60079-7 Explosive atmospheres - Part 7: Equipment protection by increased safety "e" EN / EN IEC 60079-15 Explosive atmospheres - Part 15: Equipment protection by type of protection "n" 9.1.2 EMC directive (electromagnetic compatibility) The products described in these operating instructions meet the requirements of EU directive...
  • Page 68: Declaration Of Conformity

    Siemens plc, Manchester M20 2UR You can find the current UK Declaration of Conformity for these products on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/ps/15985/cert). The SIMATIC NET products described in this document meet the requirements of the following directives: •...
  • Page 69: The Electromagnetic Compatibility Regulations 2016

    Approvals 9.2 UK Declaration of Conformity 9.2.2 The Electromagnetic Compatibility Regulations 2016 Electromagnetic compatibility The SIMATIC NET products described in these operating instructions meet the requirements of "The Electromagnetic Compatibility Regulations 2016". Applied standards: • EN 50121-3-2 Railway applications - Electromagnetic compatibility - part 3-2: Railway Vehicles - Devices •...
  • Page 70: General Approvals

    "SIMATIC NET Product Information Use of subassemblies/modules in a Zone 2 Hazardous Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages under Siemens Industry Online Support (https:// support.industry.siemens.com/cs/ww/en/view/78381013).
  • Page 71 Approvals 9.3 General approvals cULus Approval for Information Technology Equipment cULus Listed I. T. E. Underwriters Laboratories Inc. complying with • UL 62368-1 • CSA C22.2 No. 62368-1 Report no. E115352 cULus approval for industrial control equipment cULus Listed I. T. E. Underwriters Laboratories Inc.
  • Page 72 Approvals 9.3 General approvals Marking for the customs union EAC (Eurasian Conformity) Eurasian Economic Union of Russia, Belarus, Armenia, Kazakhstan and Kyrgyzstan Declaration of conformity according to the technical regulations of the customs union (TR ZU) SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...
  • Page 73: Index

    Index Accessories, 21 Installation Article numbers, 3 DIN rail, 36 Pedestal, 39 S7-1500 standard rail, 38 S7-300 standard rail, 37 Wall, 35 Button, 26 Interfaces, 19 CAx data, 63 LED display, 25, 26 Configuration manuals, 4 Loading firmware via TFTP, 27 Connecting Digital input, 47 Digital output, 48 Power supply, 23, 45 Connecting up PLUG, 27 Ethernet interface, 53 Power supply, 23, 45 Grounding, 46 Product properties, 19...
  • Page 74 Index Wall mounting, 35 Wiring, 24 SCALANCE M826 Operating Instructions, 10/2022, C79000-G8976-C362-07...

This manual is also suitable for:

Scalance m812Scalance m816

Table of Contents