Inspect each gasket for signs of twisting, cracking, wear or damage. If the
gaskets need to be replaced, cut and discard the them.
3.
Starting at the overlapping section of a patch panel groove, gently press a length
of gasket material into the groove. Work around the groove until the gasket is
seated all around the opening and in the overlapping section. Make sure the
gasket material is loose and is not stretched during installation.
Figure 2.10
4.
Trim the gasket material to length.
5.
Repeat
RUGGEDCOM MX5000RE
Installation Manual, 01/2021, C79000-G8976-1060-13
NOTICE
Do not stretch the gasket material. Stretching the gasket material will
degrade performance. If gasket material is inadvertently stretched, remove
it from the patch panel groove and allow it to sit for 8 hours before
attempting to install it again. The material will return to its original length.
Do not cut the gasket to length before assembly.
1
EMI Gasket Installation
Step 3
and
Step 4
for each patch panel opening.