Installing The Fan Tray - Siemens SIMATIC NET RUGGEDCOM MX5000RE Installation Manual

Rugged multi service platforms
Hide thumbs Also See for SIMATIC NET RUGGEDCOM MX5000RE:
Table of Contents

Advertisement

Installing the Device
2.10 Installing the Fan Tray
2.10

Installing the Fan Tray

To intall the fan tray, do the following:
1.
Position the fan tray the DB25 connectors facing forward when the fan tray is in
the RUGGEDCOM MX5000RE.
1
2
Figure 2.12
2.
Align the fan tray with the pins on the bottom of the internal mounting brackets
inside the RUGGEDCOM MX5000RE.
3.
Slide the fan tray onto the locating pins until the fan tray mount brackets touch
the RUGGEDCOM MX5000RE inner mount brackets.
4.
Secure the fan tray using six (6) screws. Use Loctite® 242 on all screws.
5.
Take the free ends of the fan control cables and straighten the cables side by
side.
6.
Take the right side fan control cable and thread it through the three (3) loops on
the left side of the fan tray.
7.
Connect the fan control cable to the left side DB25 connector.
8.
Repeat
22
2
1
#8-32×5/16" Pan Head Screw
Fan Tray
Fan Tray Installation
Step 6
and
Step 7
using the left side fan control cable.