Installing the Device
2.11 Installing the Patch Panels
1.
From the bottom of the enclosure, feed the patch panel cables through
the appropriate opening. For more information about which patch panels
correspond to which openings, refer to
1
2
Figure 2.14
2.
Align the patch panel with the screw holes surrounding the patch panel
opening.
3.
Apply Loctite® 242 to each screw.
4.
Secure the patch panel to the enclosure with eight (8) screws for large panels,
or four (4) for small panels. Hand-tighten the screws evenly in a cross pattern.
There should be no visible gap between the patch panel and the enclosure's
bottom plate when properly tightened. Pay careful attention to avoid damaging
the cables and gaskets.