Nortel 600 Series Manual page 22

Dip switch settings for printed circuit packs and balance networks
Hide thumbs Also See for 600 Series:

Advertisement

2-15 Switch settings for printed circuit packs
Switch 2 is not used on 2T32AD and earlier vintage packs; settings for this switch on
2T32AE and later vintage packs are shown in Table 2-N.
Table 2-N:
NT2T32AE (and later) Carrier Interface pack switch settings - for mode selection
Mode
Normal
Timeslot 1 is a voice channel
DLC
Timeslot 1 is a 56 kbit/s data link
DLC/OSS
Timeslot 1 is a 48 kbit/s data link
and a 1.2 kbit/s
(1200 baud) data link for OSS telemetry
Switch 9 is not used on 2T32AE and earlier vintage packs; settings for this switch on
2T32AF and later vintage packs are shown in Table 2-O.
Table 2-O:
N2T32AF (and later) Carrier Interface pack switch settings - for mode selection
Mode
Normal
Timeslot 1 is a voice channel
DLC
Timeslot 1 is a 56 kbit/s data link
DLC/DAS
Timeslot 1 is a 40 kbit/s data link and a 1.2
kbit/s
(1200 baud) data link for OSS telemetry
NTP 297-3601-316
Settings: 1 = ON, 0 = OFF, - = NOT APPLICABLE.
Note:
Settings: 1 = ON, 0 = OFF, - = NOT APPLICABLE.
Note:
For Generic 602.20
Switch (switch position 2)
1
2
3
4
-
0
-
-
-
0
-
-
-
1
-
-
Switch (switch position 9)
1
2
3
4
-
-
-
-
-
0
-
-
-
1
-
-
08.01
5
6
7
8
-
-
-
-
-
-
-
-
-
-
-
-
5
6
7
8
9
-
-
-
-
1
-
-
-
-
0
-
-
-
-
0
August 2006

Advertisement