Download Print this page

Nortel 600 Series Manual page 171

Dip switch settings for printed circuit packs and balance networks
Hide thumbs Also See for 600 Series:

Advertisement

Table 3-X:
(Continued)
QNB65C Balance Network - switch settings for 26-gauge end-section D66 loaded cable
SQ Switches
1
2
3
4
0
0
1
0
Length
Ft X 1000 Meters
3.2-3.3
975-1005
3.3-3.4
1005-1036
3.4-3.5
1036-1066
3.5-3.6
1066-1097
3.6-3.7
1097-1127
3.7-3.8
1127-1158
3.8-3.9
1158-1188
3.9-4.0
1188-1219
4.0-4.1
1219-1249
4.1-4.2
1249-1280
4.2-4.3
1280-1310
4.3-4.4
1310-1341
4.4-4.5
1341-1371
August 2006
5
6
7
8
0
1
0
1
Capacitance(µ
SS Switches
F)
1
5
33.750
0
1
34.875
1
1
36.000
0
0
37.125
1
0
38.250
0
0
39.375
1
0
40.500
0
0
41.625
1
0
42.750
0
0
43.875
1
0
45.500
0
1
46.125
1
1
47.250
0
1
Settings: 1 = ON, 0 = OFF
Note:
For Generic 602.20
Switch settings for balance networks
Resistance
2
3
4
Value (Ω)
6
1
1
1
300
0
1
1
1
320
0
0
0
1
320
1
0
0
1
340
1
1
0
1
340
1
1
0
1
360
1
0
1
1
360
1
0
1
1
380
1
1
1
1
380
1
1
1
1
380
1
0
0
0
400
1
0
0
0
400
1
1
0
0
420
1
08.01
3-35
ST Switches
1
2
3
4
5
0
0
0
0
1
1
1
1
1
0
1
1
1
1
0
0
1
1
1
0
0
1
1
1
0
1
0
1
1
0
1
0
1
1
0
0
0
1
1
0
0
0
1
1
0
0
0
1
1
0
1
1
0
1
0
1
1
0
1
0
0
1
0
1
0
NTP 297-3601-316

Advertisement

loading