Dip switch settings for printed circuit packs and balance networks
Hide thumbs Also See for 600 Series:

Advertisement

Table 2-DR:
QPP519 Fault Locate Order Wire pack - switch settings for the fault pair termination option
Option
Fault pair terminated
Bridged
Table 2-DS:
QPP519 Fault Locate Order Wire pack - switch settings for the fault pair termination option
Fault-Locate Jack Attenuation Option
15 dB
0 dB
Table 2-DT:
QPP519 Fault Locate Order Wire pack - switch settings for the signal loopback option
Signal Loopback Option
Loopback enabled
No loopback
Table 2-DU:
QPP519 Fault Locate Order Wire pack - switch settings for the fault pair power source option
Fault Pair Power Source Option
External V+
-48 V battery
August 2006
Note: Set switches toward option to be selected.
Note: Set switches toward option to be selected.
Note: Set switches toward option to be selected.
Note: Set switches toward option to be selected.
For Generic 602.20
Switch settings for printed circuit packs
08.01
Switch 5 Position
J
K
Switch 6 Position
E
F
Switch 10 Position
U, S
V, T
Switch 11 Position
L
M
NTP 297-3601-316
2-126