Parameter
Parameter Group
Number
9901
9902
9904
9905
START--- UP
DATA
9906
9907
9908
9909
1001
1002
START/STOP/DIR
1003
1301
ANALOG INPUTS
1302
1401
RELAY OUTPUTS
1402
1403
1601
SYSTEM
CONTROL
1608
1701
1702
OVER RIDE
1703
1704
1705
2003
LIMITS
2007
2008
2101
START/STOP
2102
2202
ACCEL/DECEL
2203
2601
MOTOR
2605
2606
FAULT
3006
FUNCTIONS
All Other Parameter Settings are ABB Drive Default Settings
APPENDIX B - VFD INFORMATION (CONT)
Table 40 — VFD CONFIGURATIONS
APPLICATION CRITICAL DRIVE PARAMETERS FOR ABB ACH550 DRIVES
Description
HK30WA001--- 208/230V
Language
Application Macro
Motor Control Mode
Motor Nominal Voltage
Motor Nominal Current
Motor Nominal Frequency
Motor Nominal Speed
Motor Nominal Power
EXT1 Commands
EXT2 Commands
Direction
Minimum Al --- 1
Maximum Al --- 1
Relay Output 1
Relay Output 2
Relay Output 3
Run Enable
Start Enable 1
Override Set
Override Freq
Override Speed
Over Pass Code
Override
Maximum Current
Minimum Frequency
Maximum Frequency
Start Function
Stop Function
Accelerate Time
Decelerate Time
Flux Optimization
Volt/Freq Ratio
Switching Frequency
Motor Thermal Time
Value
HK30WA008--- 460V
(0) English
(1) HVAC Default
(3) Scalar : Freq
230
460
7.0
3.5
60
1725
2.4
(1) DI --- 1 Start/Stop
(1) DI --- 1 Start/Stop
(1) Forward
20
100
(7) Started
(2) Run
(3) Fault ( ---1)
(0) Not Set
(4) DI --- 4
(3) DI --- 3
60
1750
0
On
8.0
4.0
0
60
(8) Ramp
(2) Ramp
30
30
(1) On
(2) Squared
8
1050
82
UNITS
NOTE
---
ABB Drive default
PD Product specific
---
setting
---
ABB Drive default
PD Product specific
Volts
setting
PD Product specific
Amps
setting
Hz
ABB Drive default
PD Product specific
RPM
setting
PD Product specific
HP
setting
---
ABB Drive default
---
ABB Drive default
PD Product specific
---
setting
%
ABB Drive default
%
ABB Drive default
Carrier default settings
---
from PPS
---
ABB Drive default
---
ABB Drive default
---
ABB Drive default
---
ABB Drive default
Carrier default settings
---
from PPS
Carrier default settings
Hz
from PPS
Carrier default settings
RPM
from PPS
Carrier default settings
---
from PPS
Carrier default settings
---
from PPS
PD Product specific
Amps
setting
Hz
ABB Drive default
Hz
ABB Drive default
PD Product specific
---
setting
PD Product specific
---
setting
Seconds
ABB Drive default
Seconds
ABB Drive default
PD Product specific
---
setting
Carrier default settings
---
from PPS
Carrier default settings
kHz
from PPS
Carrier default settings
Seconds
from PPS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

48pd0548pd0650pd0550pd06

Table of Contents