7.

DSC/WATCH RECEIVER SETUP

7.1 Setting Alarms

The Alarm menu enables/disables internal and external alarms. Note that the
Distress/Urgency alarm cannot be disabled. Press the [#/SETUP] key at the DSC standby
screen, choose ALARM and then push the [ENTER] knob to display the Alarm menu.
Alarm setup
****
INTERNAL AUDIO ALARM
RCVD CALL
OLD POSITION
POSITION OLDER
EXT ALARM : DSTRS/URG
Default: ON
Disables/enables alarm for received Safety,
OFF
ON
Ship's Business and Routine calls.
Rotate
[ENTER]
knob to choose.
Default: ON
Disables/enables old position alarm in manual
OFF
ON
position entry mode, which alerts the operator
when position data is older by the number of
hours or minutes set in the Position Older field.
***
: ON
: ON
: 4.0 H
Default: 4.0 hours
Alarm is output when position is older by the
4.0
3.0
number of hours set here.
2.0
1.0
0.5
Default: DSTRS/URG
DSTRS/URG
ROUTINE
ALL
OFF
Note: Alarm for Distress and Urgency calls
cannot be disabled.
WATCH KEEPING
AUTO ACK
DISTRESS
2187.5
6312.0
4207.5
Warning:
16804.5
12577.0
8414.5
ROUTINE
Update position
2177.0
6331.0
4219.5
16903.0
12657.0
8436.5
35˚00.000N 135˚00.000E 23:59
VOLUME
Message shown when manually
entered position is older than the
time set on the Alarm setup menu.
Sets type of call to be output to the
Incoming Indicator IC-303-DSC.
DSTRS/URG: Distress or urgency
call output upon receipt.
ROUTINE:
Routine call output
upon receipt.
ALL:
All calls output.
OFF:
No output.