Alert
Priority Condition
Code
611
Service Urgent
700
Service Urgent
703
Service Soon
Table 7. Alert Codes and Troubleshooting
Actual Displayed
Alert Text Under
Component or System Operational
dealer control center
State and Troubleshooting Tip
> Notifications
This alert will automatically notified the user that a
high room temperature condition exist. A notification
is displayed on the HD display and email notification
sent to homeowner and dealer.
The heat alert protection parameter range is 80°F
to 100°F (26.67 to 37.78°C). Default is 90°F
High Room
(32.22°C).
Temperature
Detected
NOTE:
The HD display's internal temperature sensor is not
operating correctly. To resolve this issue, try the fol-
lowing:
• Remove HD display from mag-mount and
reattaching.
Thermostat Temp
Sensor Problem
• Seal hole in wall behind mag-mount to minimize
exposure to unconditioned air from inside the wall.
• Run "reset all" under dealer control center.
• If issue persist, then replace the HD display.
Thermostat Humid
Thermostat Humid Sensor Problem. Sensor is dam-
Sensor Problem
aged or data is corrupted possibly..
Notification is dependent on
the thermostat having a active
Wi-Fi connection and the user
account has been setup and
includes a valid email address.
37
How to clear
alert code
Automatically clears when
condition is resolved.
Automatically clears when
the system detects that the
issue no longer exists.
First try a system reset, then
if persists the thermostat
would need replacement.