Lennox iComfort M30 Installation And Setup Manual page 16

Smart thermostat
Hide thumbs Also See for iComfort M30:
Table of Contents

Advertisement

MENU
Humidifier
SYSTEM SETUP
Dehumidifier
OUTDOOR SENSOR
RESIDUAL COOL
BALANCE POINT
Table 5. Advanced Settings
SETTING (default is bold)
Not Installed
Humidification
Not Installed
Humiditrol - Min
Humiditrol - Mid
Humiditrol - Max
Auxiliary Dehumidifier
The Humiditrol settings provides adjustment of Humiditrol overcooling operation. Overcooling
from two degrees below the cooling set point down to two degrees above the heating set point
is provided. The minimum overcooling of two degrees below the cooling set point is represented
by "MIN". The maximum overcooling of two degrees above the heating set point or 65°F is
represented by "MAX". Halfway between is represented by "MID". The default is
Yes or No
0, 30, 60, 90, 120 seconds, -300 (5 minute delayed)
Disabled or Enabled
Setting used to prevent the heat pump
from heating the structure. The outdoor
temperature is below the level where the heat
pump is programmed to heat the home).
NOTE: Balance point option will not
appear on the menu until system is
configured correctly and a outdoor
temperature sensor is installed and
enabled in the thermostat.
16
Notes:
These options only appear under System
Setup if the H/D and ACC terminals have been
enabled for the specific type of accessory.
Go to Terminal Settings to enabled attached
accessory for the specific terminal being used.
Required for high and low balance points
options.
When enabled:
Low Balance Point: 25°F (-20 to 72°F)
Adjustments are in increments of 1°F (0.56°C).
Setting used to prevent the heat pump from
heating the structure. (Alert 18 - Minor -
Notification only - The outdoor temperature
is below the level where the heat pump is
programmed to heat the home).
"MAX".