Lennox iComfort M30 Installation And Setup Manual page 21

Smart thermostat
Hide thumbs Also See for iComfort M30:
Table of Contents

Advertisement

MENU
VCM = ASHRAE and
Ventilation Outdoor Condition
Override is set to ENABLED
STAGE 2 HP LOCK TEMP
COMPRESSOR PROTECT
DISPLAY PERFORMANCE REPORT
H/D
TERMINAL SETTINGS
ACC
O/B
SYSTEM TEST MODE
RESET SETTING
RESTART
Table 5. Advanced Settings
SETTING (default is bold)
Fresh Air Damper Ventilation CFM
Off, 40°F, 45°F, 50°F, 55°F
On or Off
On or Off
Off
Humidify
Dehumidify
Off
Humidify
Dehumidify
Ventilation
O (energized during cooling)
B (energized during heating)
Confirm Button
Confirm Button
Confirm Button
21
Notes:
Default is 75 CFM. Range is 20 to
250 CFM
Heat Pump - for dual-fuel applications (locks
out 2nd stage compressor)
This feature prevents the compressor from
being short cycled any time the compressor is
turned "OFF".
Installer run tests to check all output relays.
Tests confirm signals between thermostat/unit
are being sent/received. Stops system to run
system tests
Resets all parameters to factory settings
Reboot the thermostat.