MENU
VENTILATION SETTINGS
VCM = ASHRAE and
Ventilation Outdoor Condition
Override is set to DISABLED.
VCM = ASHRAE and
Ventilation Outdoor Condition
Override is set to ENABLED.
Table 5. Advanced Settings
SETTING (default is bold)
Ventilator Type: Fresh Air Damper
VENTILATION CONTROL MODE (VCM): ASHRAE or Timed
Relay Setting to Work Fresh Air Damper
Ventilation Minutes Per Hour
VCM = TIMED
Ventilation High Outdoor Temperature Limit
Ventilation Low Outdoor Temperature Limit
Ventilation High Outdoor Dew Point Limit
Relay Setting to Work Fresh Air Damper
ASHRAE Compliance Check
ASHRAE Infiltration Credit
ASHRAE house floor area serviced by this
ventilator
ASHRAE Number of Bedrooms
Fresh Air Damper Ventilation CFM
Ventilation High Outdoor Temperature Limit
Ventilation Low Outdoor Temperature Limit
Ventilation High Outdoor Dew Point Limit
ASHRAE Compliance Check
ASHRAE Infiltration Credit
ASHRAE house floor area serviced by this
ventilator
ASHRAE Number of Bedrooms
Notes:
Closed or Open. Default is Closed.
Default is 20 minutes. Range is 0 to 60 minutes
Default is 100⁰F. Range is 60⁰F to 115⁰F.
Default is 0⁰F. Range is -20⁰F to 55⁰F.
Default is 55⁰F. Range is 45⁰F to 80⁰F.
Closed or Open. Default is Closed.
YES or No: Current settings comply with
ASHRAE 62.2.
Default is 0 CFM. Range is 0 to 200 CFM.
Default is 2500 square feet. Range is 500 to
5000 square feet.
Default is 3. Range is 1 to 10.
Default is 75 CFM. Range is 20 to 250 CFM.
Default is 100⁰F. Range is 60⁰F to 115⁰F.
Default is 0⁰F. Range is -20⁰F to 55⁰F.
Default is 55⁰F. Range is 45⁰F to 80⁰F.
YES or No: Current settings comply with
ASHRAE 62.2.
Default is 0 CFM. Range is 0 to 200 CFM.
Default is 2500 square feet. Range is 500 to
5000 square feet.
Default is 3. Range is 1 to 10.
20