Alert
Priority Condition
Code
180
Service Soon
610
Service Urgent
Table 7. Alert Codes and Troubleshooting
Actual Displayed
Alert Text Under
Component or System Operational
dealer control center
State and Troubleshooting Tip
> Notifications
The thermostat has found a problem with the outdoor
temperature sensor. In normal operation after system
component control recognizes sensors, the alert code
will be sent if valid temperature reading is lost.
• Compare
temperature / resistance charts in unit installation
Outdoor Temperature
instructions. Replace sensors pack if necessary.
Sensor Problem
• At the beginning of (any) configuration, furnace,
air-handler control or equipment interface module
will detect the presence of the sensor(s).
• If detected (reading in range), appropriate feature
will be set as 'installed' and shown in the 'About'
screen.
This alert will automatically notified the user that a low
room temperature condition exist. A notification is dis-
played on the HD display and email notification sent
to homeowner and dealer.
The freeze alert protection parameter range is 30°F to
Low Room
50°F (-1.11 to 10.0°C). Default is 40°F (4.44°C).
Temperature
Detected
NOTE:
outdoor
sensor
resistance
Notification is dependent on
the thermostat having a active
Wi-Fi connection and the user
account has been setup and
includes a valid email address.
36
How to clear
alert code
to
Automatically clears upon
configuration, or sensing
normal values.
Automatically clears when
condition is resolved.