Electrical power supply wiring
b
Wire terminals
c
Screws
d
Wire clamp
e
Screws
f
Right side plate assembly
3 Connect the electrical power supply wiring to the wire terminals.
4 Install the wire clamp and fix it using the screws.
5 Connect all connectors to the main PCB.
INFORMATION
Use the wiring diagram and connection diagram for correct installation of the
connectors, see
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
6 Fix the wiring to the switch box using a new cable tie.
b
"5.2 Wiring
diagram" [
4
 137].