Daikin Split Comfora R32 Service Manual page 109

Hide thumbs Also See for Split Comfora R32:
Table of Contents

Advertisement

ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01C – 2020.07
5 Install the swing raster motor assembly on the correct location in the indoor
unit using the 2 screws.
a
Swing raster motor cover
b
Swing raster motor assembly
c
Screw
6 Tighten the 2 screws that fix the swing raster motor to the bracket.
7 Install the swing raster motor cover.
8 Put the switch box in place.
a a
a
Grouding wire screw
b
Heat exchanger thermistor
c
Indoor unit PCB
d
Switch box screw
e
Switch box
9 Route the connectors of the indoor unit fan motor, swing flap motor and
swing raster motor (if equipped) inside the switch box and connect them to
the indoor unit PCB.
10 Install and tighten the screw to secure the switch box.
11 Install the heat exchanger thermistor in its holder.
12 Connect the grounding wires to the heat exchanger using the screws.
Is the problem solved?
Yes
No
b
c
a
b
d
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
2
Components
|
e
c
Service manual
109

Advertisement

Table of Contents
loading

Table of Contents