To install the reactor
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01C – 2020.07
2 Open the compressor insulation.
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
3 Remove the cover of the compressor wire terminals.
a
Compressor wire terminals cover
4 Disconnect the connector.
5 Remove the clip and remove the reactor from the compressor.
6 To install the reactor, see
1 Install the reactor in the correct location and install the clip.
2 Connect the reactor connector.
3 Install the cover of the compressor wire terminals.
a
Compressor wire terminals cover
4 Install the compressor insulation.
Is the problem solved?
Yes
a
"2.11.2 Repair
procedures" [
a
Action
No further actions required.
2
Components
|
4
 102].
Service manual
103