Daikin Split Comfora R32 Service Manual page 120

Hide thumbs Also See for Split Comfora R32:
Table of Contents

Advertisement

2
|
Components
Repair procedures
To remove the room thermistor PCB
To install the room thermistor PCB
Service manual
120
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Locate the room thermistor PCB on the indoor unit PCB.
2 Disconnect the connector of the room thermistor PCB from the indoor unit
PCB.
3 Press the latches to unlock and remove the room thermistor PCB from the
indoor unit PCB.
4 To install the room thermistor PCB, see
1 Install the room thermistor PCB in the correct location on the indoor unit PCB.
2 Connect the connector of the room thermistor PCB to the indoor unit PCB.
Is the problem solved?
Yes
No
"2.10 Plate
work" [
"Repair
procedures" [
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
4
 92].
4
 112].
Split Comfora R32
ESIE18-01C – 2020.07

Advertisement

Table of Contents
loading