Daikin Split Comfora R32 Service Manual page 84

Hide thumbs Also See for Split Comfora R32:
Table of Contents

Advertisement

2
|
Components
Problem solved?
Repair procedures
To remove the propeller fan blade assembly
Service manual
84
Pulses are measured during fan blade
propeller rotation?
Yes
No
After all checking procedures listed above have been performed:
Is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
1 Remove the required plate work, see
2 Remove the nut that fixes the propeller fan blade assembly.
a
Nut
b
Propeller fan blade assembly
3 Pull and remove the propeller fan blade assembly from the DC fan motor
assembly.
INFORMATION
Use a pulley remover if the propeller cannot be removed manually.
Action
Perform a check of the main PCB, see
"2.8.1 Checking
Replace the DC fan motor, see
procedures" [
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
"2.10 Plate
a
b
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
4
procedures" [
 75].
"Repair
4
 84].
4
work" [
 92].
Split Comfora R32
ESIE18-01C – 2020.07

Advertisement

Table of Contents
loading