Outputting a Tally Signal

Pins 1–16 of the TALLY/GPIO connector can be used to output a tally.
A tally signal is output from the connector pins whenever a cross-
point button is selected.
Ó
1 .
[MENU] button
"RS-232/TALLY/GPO/GPI"
Ó
select "TALLY/GPO 1"–"TALLY/GPO 16," and press the
[VALUE] knob.
2 .
Use the [VALUE] knob to select the tally signal assigned to
the connector pins and then press the [VALUE] knob.
Value
Explanation
PGM HDMI 1–8
Final output selection is HDMI IN 1–8
PGM SDI 1–8
Final output selection is SDI IN 1–8
PST HDMI 1–8
Preview output selection is HDMI IN 1–8
PST SDI 1–8
Preview output selection is SDI IN 1–8
3 .
Press the [MENU] button to close the menu.
MEMO
Use a settings template to change the assignments for the
connector pins all at once.
Select a template from "TEMPLATE" in the TALLY/GPO menu and
then press the [VALUE] knob to apply the settings.

Outputting a Control Signal

You can use connector pins 1–16 of the TALLY/GPIO connector as
GPOs to output control signals.
Assigning the GPOs
Ó
"TALLY/GPO"
You can assign pins 1–16 of the TALLY/GPIO connector to the GPOs
(1–16) in order to output control signals.
1 .
[MENU] button
Ó
[VALUE] knob.
2 .
Use the [VALUE] knob to select one of "GPO 1"–"GPO 16,"
and press the [VALUE] knob.
3 .
Press the [MENU] button to close the menu.
MEMO
Use a settings template to change the assignments for the
connector pins all at once.
Select a template from "TEMPLATE" in the TALLY/GPO menu and
then press the [VALUE] knob to apply the settings.
Outputting a control signal
Control signals are outputted when you operate a USER button,
footswitch or other control to which a GPO output function has been
assigned.
Using the USER buttons
The USER buttons light up while control signals are being output.
Ø
"Assigning Functions to the USER Buttons" (p. 65)
Using a footswitch
Ø
"Using a Footswitch" (p. 68)
Inputting an external control signal (GPI)
Ø
"Inputting a Control Signal" (p. 70)
Ó
"RS-232/TALLY/GPO/GPI"
select "TALLY/GPO 1"–"TALLY/GPO 16," and press the
Other Functions
Ó
"TALLY/GPO"
71