Control Using the TALLY/GPIO and RS-422 Connector

In addition to tally signal output functionality, control signal input/output functionality is also provided, allowing you to transmit or receive
control signals to or from an external device.

Specification of the TALLY/GPI Connector

Pin layout
13
12
11
10
25
24
23
22
DB-25 type (female)
Tally output
Trigger method
Open collector
Maximum input
12 V/200 mA
Control input
Trigger method
No-voltage contact (make-contact) triggering
Contact capacity
DC 24 V 0.1 A or higher
Input method
Photocoupler

Inputting a Control Signal

To operate the XS-62S remotely using control-signal input, you first
assign the function to a GPI channel (1 through 8).
Select the [MENU] button 0 "REMOTE" 0 "GPI 1
1
TYPE" through "GPI 8 TYPE."
2
Use the [VALUE] knob to specify the function to
assign to the GPI channel (1 through 8).
Value
Explanation
N/A
No function is assigned.
PGM CH SEL 1–8
This switches the final output video.
This switches the preset video (the video to
PST CH SEL 1–8
be output next).
MEMORY LOAD
This loads a preset memory.
1–8
During DSK compositing, this switches the
DSK SRC SEL 1–8
channel of the overlaid logo or image.
3
Press the [VALUE] knob to apply the setting.
4
Press the [MENU] button to quit the menu.
When a control signal is input from an external source, the assigned
function is executed. The GPI trigger is fixed at the trailing edge
(low: ON).
9 8 7 6
5 4 3 2 1
21
20
19
18
17
16
15
14
Pin assignments
Pin #
Function
1
TALLY 1 PGM
2
TALLY 1 PST
3
TALLY 2 PGM
4
TALLY 2 PST
5
TALLY 3 PGM
6
TALLY 3 PST
7
TALLY 4 PGM
8
TALLY 4 PST
9
TALLY 5 PGM
10
TALLY 5 PST
11
TALLY 6 PGM
12
TALLY 6 PST
13
GPO 1

Outputting Tally Signals or Control Signals

Tally signals or GPO control signals can be output from the TALLY/
GPIO connector.
Outputting a Tally Signal
A tally signal is output from the connector pin corresponding to
the video channel being output, also including video composition
and transition effects.
Outputting a GPO Signal
By switching [SW MODE] to GPO/CAMERA mode, you can output
control signals by operating cross-point buttons [1]–[4].
Select the [MENU] button 0 "REMOTE" 0 "GPO 1
1
TYPE" through "GPO 8 TYPE."
2
Use the [VALUE] knob to set the operating mode of
the GPO channel.
Value
Explanation
When you press a cross-point [1]–[4] button, a
ONE SHOT
GPO signal is output for 0.5 seconds.
Each time you press a cross-point [1]–[4] button,
ALT
the GPO signal output turns on/off.
3
Press the [VALUE] knob to apply the setting.
4
Press the [MENU] button to quit the menu.
25
Pin #
Function
14
GPO 2
15
GPO 3
16
GPO 4
17
GND
18
GPI 1
19
GPI 2
20
GPI 3
21
GPI 4
22
GPI 5
23
GPI 6
24
GPI 7
25
GPI 8