9. Close the door.
When the door is closed, an automatic
system will automatically draw in any
residual water in the loading wand to
avoid drips. A bubbling noise may be
heard; this is completely normal.
10. Touch the FULL RESERVOIR CALIBRATION
button
to complete calibration.
11. Wait for the end of calibration.
On completion, a warning on the display
indicates the end of the calibration procedure.

INSTALLATION

Electrical connection

See General safety instructions.
General information
Check the mains characteristics against the data
indicated on the plate.
The identification plate bearing the technical
data, serial number and brand name is visibly
positioned on the appliance.
Do not remove this plate for any reason.
The appliance must be connected to ground
using a wire that is at least 20 mm longer than
the other wires.
The appliance can work in the following modes:
• 220-240 V~
3 x 1.5 mm² three-core cable.
The values indicated above refer to the
cross section of the internal lead.
91477A081/A
12. Touch the CONFIRM
reservoir calibration procedure.
The display suggests to drain the water from the
reservoir. You can either use the water for steam
cooking or proceed as described in the chapter
for Reservoir draining.

Extraordinary maintenance

Seal maintenance tips
The seal should be soft and elastic.
• To keep the seal clean, use a non-abrasive
sponge and wash with lukewarm water.
The aforementioned power cables are
sized taking into account the
coincidence factor (in compliance with
standard EN 60335-2-6).
Fixed connection
Fit the power line with an all-pole circuit breaker
with a contact separation distance sufficient to
provide complete disconnection in category III
overvoltage conditions, pursuant to installation
regulations.
For the Australian/New Zealand market:
The circuit breaker incorporated in the fixed
connection must comply with AS/NZS 3000.
Connection with plug and socket
Make sure that the plug and socket are of the
same type.
Avoid using adapters, gang sockets or shunts as
these could cause overheating and a risk of
burns.
button to end the
INSTALLATION - 133