Displaying In Info Mode - Biasi Inovia 16S User Manual

Table of Contents

Advertisement

In order to reset good function-
ing of the boiler, call a compe-
tent and responsible Service
Engineer.
Noise due to air bubbles are heard dur-
ing operation
You should check that the pressure on the
pressure gauge is not below the correct set-
ting.
If required, top up the system correctly, as
described in the section "Refilling proce-
dure" to page 14 of this manual. Bleed any
air present in the radiators, if necessary.
The pressure has gone down
It is necessary to top up the appliance with
water again, so as to raise the pressure to
an adequate level as described in the sec-
tion "Refilling procedure" to page 14 of this
manual. If topping up with water has to
be done very frequently, have the system
checked for leaks.
Water comes out of the pressure relief
valve
Check on the pressure gauge that the pres-
sure in the central heating circuit is not
close to 3 bars. In this case, temperature
rise in the circuit can cause the pressure
relief valve to open. So that this does not
happen and to decrease the pressure to a
normal value, it is advisable to vent some of
the water in the appliance through the bleed
valves present in the radiators.
Water should occasionally leak from the
boiler
Shut off the valves positioned under the
boiler to page 21 and call an Authorised
Service Centre Engineer.
- 24 -
USEFUL ADVICE
3.7
The INFO mode allows the display of some
information on the boiler functioning status.
In case of malfunctioning of the boiler, it may
be useful to communicate such information
to the Authorised Service Centre Engineer
so that the causes can be understood.
In order to access the INFO mode, press
key 14 (Fig. 3.5) the index J00 and the val-
ue of the parameter appear on the display
(Fig. 3.6).
9
10
11
Fig. 3.5
Fig. 3.6
To scroll the values press 15 (reduce) and
In this case or in case of prob-
lems other than those men-
tioned here, switch off the boil-
er, as described in section
"Extinguishing" to page 20 and
call a competent and responsi-
ble Service Engineer.

Displaying in INFO mode

12 13
17
16
15
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Inovia 25s41-583-2541-583-26

Table of Contents