Displaying In Info Mode - Biasi ADVANCE 25S User Manual

Hide thumbs Also See for ADVANCE 25S:
Table of Contents

Advertisement

ter again, so as to raise the pressure to an ad-
equate level as described in the section "Re-
filling procedure" on page 12 of this manual.
If topping up with water has to be done very
frequently, have the system checked for leaks.
Water comes out of the pressure relief
valve
Check on the pressure gauge that the pres-
sure in the central heating circuit is not close
to 3 bars. In this case, temperature rise in the
circuit can cause the pressure relief valve to
open. So that this does not happen and to
decrease the pressure to a normal value, it
is advisable to vent some of the water in the
appliance through the bleed valves present in
the radiators.
If before water should occasionally leak
from the boiler
Shut off the valves positioned under the boiler
to page 15 and call an Authorised Service
Centre Engineer.
In this case or in case of problems
other than those mentioned here,
switch off the boiler, as described
in section "Switching off" on page
15 and call a competent and re-
sponsible Service Engineer.
3.7

Displaying in INFO mode

The INFO mode allows the display of some
information on the boiler functioning status. In
case of malfunctioning of the boiler, it may be
useful to communicate such information to the
Authorised Service Centre Engineer so that
the causes can be understood.
In order to access the INFO mode, press keys
12 and 14 (Fig. 3.5) at the same time until the
letter d appears on the display that alternates
with a code (Fig. 3.6).
- 18 -
USEFUL ADVICE
Fig. 3.5
Fig. 3.6
To scroll the values press 13 (reduce) and
14 (increase) keys. In order to exit the INFO
mode, hold keys 12 and 14 (Fig. 3.5) pressed
at the same time.
The table summarises the possible values vis-
ible in INFO mode.
Value visualised
Primary circuit pressure (not
present)
External temperature
K curve value configured in
settings
Offset climatic curve value
Calculated heating set point
(with climatic curve or set
configured)
Temperature NTC delivery
Temperature NTC return (not
present)
14
13
12
Index
d0 + - -
d1 + value
d2 + value
d3 + value
d4 + value
d5 + value
d6 + - -