Filters; System Charge Adjustments - Trane TAM7A0A24H21SC Installer's Manual

Table of Contents

Advertisement

Filters

Table 22. Filter Considerations
A filter must be installed within the system.
A filter channel is provided in the unit at the bottom of the Blower/
Filter compartment.
For customer ease of filter maintenance, it is recommended that a
properly sized remote filter grill(s) be installed for units that are
difficult to access. Airflow should not exceed the maximum rated
velocity of the filter being used.
Table 23. Filter Sizes
Cabinet Size *
A
Filter Size
16 x 20
* Cabinet size is indicated by the 7th digit in model number.

System Charge Adjustments

System Matched with:
Single Compressor
2–Stage HP
Single Compressor
2–Stage AC
Two Compressor
2–Stage HP
Two Compressor
2–Stage HP
NOTES:
1. Variable Speed outdoor units must be charged per the outdoor unit instructions.
2. All other matches must be charged per the nameplate charging instructions.
46
B
C
20 x 20
22 x 20
Indoor Unit Model No.
TAM7A0B30H21SC
TAM7A0C36H31SC
TAM7A0C48H41SC
TAM7A0B30H21SC
TAM7A0C36H31SC
TAM7A0C48H41SC
TAM7A0B30H21SC
TAM7A0C36H31SC
TAM7A0C48H41SC
TAM7B0C60H51SB
TAM7A0B30H21SC
TAM7A0C36H31SC
TAM7A0C48H41SC
Filte r in a ir h a n d le r
cabi net
(Up flo w Ap p lica tio n )
Outdoor Unit Model No.
4A6H6024E/G, 4TWX6024E/G
4A6H7024, 4TWX8024
4A6H6036E/G, 4TWX6036E/G
4A6H7036, 4TWX8036
4A6H6048E/G, 4TWX6048E/G
4A6H7048, 4TWX8048
4A7A6024E/G, 4TTX6024E/G
4A7A7024, 4TTX8024
4A7A6036E/G, 4TTX6036E/G
4A7A7036, 4TTX8036
4A7A6048E/G, 4TTX6048E/G
4A7A7048, 4TTX8048
4TWZ0024A, 4A6Z0024A
4TWZ0036A/B, 4A6Z0036A/B
4TWZ0048A/B, 4A6Z0048A/B
4TWZ0060A, 4A6Z0060A
4TTZ0036A/B, 4A7Z0024A
4ATTZ0036A/B, 4A7Z0036A/B
4TTZ0048A/B, 4A7Z0048A/B
Subcooling
10°
10°
12°
12°
11°
13°
18-GJ06D2-2A