Trane TAM7A0A24H21SC Installer's Manual page 39

Table of Contents

Advertisement

D D i i p p S S w w i i t t c c h h S S 2 2
Set the S2–1 and S2–2 dip switches for the Cooling
and Heating CFM/Ton.
INDOOR MODEL
S2–1 S2–2
OFF
OFF
TAM7A0A24H21SC
ON
ON
OFF
OFF
TAM7A0B30H21SC
ON
ON
OFF
OFF
TAM7A0C36H31SC
ON
ON
OFF
OFF
TAM7A0C42H31SC
ON
ON
OFF
OFF
TAM7A0C48H41SC
ON
ON
OFF
OFF
TAM7B0C60H51SB
ON
ON
Set the S2–3 and S2–4 dip switches for the Blower
Off and Delay.
BLOWER OFF DELAY
1.5M @ 100%
NO DELAY
3M @ 50%
ENHANCED
I I n n d d o o o o r r B B l l o o w w e e r r T T i i m m i i n n g g
This ENHANCED MODE selection provides a ramping
up and ramping down of the blower speed to provide
improved comfort, quietness, and potential energy
savings. The graph on the right shows the ramping
process. Enhanced Mode works in cooling, HP , heating,
Torque, and constant CFM modes.
Set the S2–5 dip switch for the airflow mode.
AIRFLOW MODE
*TORQUE
CONSTANT CFM
18-GJ06D2-2A
COOLING
HEATING
CFM/TON
CFM/TON
OFF
400
430
ON
360
390
OFF
380
410
ON
420
450
OFF
400
430
ON
360
390
OFF
380
410
ON
420
450
OFF
370
420
ON
350
400
OFF
390
440
ON
410
450
OFF
370
400
ON
330
360
OFF
350
380
ON
390
420
OFF
350
400
ON
330
380
OFF
370
420
ON
390
440
OFF
370
400
ON
380
410
OFF
390
420
ON
400
430
S2–3
S2–4
OFF
OFF
OFF
ON
ON
OFF
ON
ON
S2–5
OFF
ON
OUTDOOR
OUTDOOR
HP
1
1
R4
S1
C1
R NET 1
R NET 2
R1
U1
Co o l Off De la y
R13
R14
Airflo w Co n tro l (AFC)
80%
Dehumidify
50%
Fast Coil Cooling
OFF
1
7.5
minute
minutes
CCOMPRE
SSO R OPERATION
All zoning applications MUST be set to Constant
CFM mode.
Torque mode is optional and is recommended for
high static applications. High static conditions
dramatically increase energy consumption with
variable speed motors. Evaluate the blower
performance table in relationship to the duct
system to determine the benefit of each installation.
For the 2 ton air handler, torque mode will reduce
airflow when static is above approximately 0.3"
water column.
For the 2–1/2, 3, and 3–1/2 ton air handlers, torque
mode will reduce airflow when static is above
approximately 0.35" water column.
For the 4 and 5 ton air handlers, torque mode will
reduce airflow when static is above approximately
0.4" water column.
When selected, Torque Mode is used for cooling
operation only.
All heating modes default to constant CFM.
D D i i p p S S w w i i t t c c h h e e s s
on
}
Ca p a c ity (To n s )
AC (S ys te m)
2 (S ta g e s )
2 (Co mp re s s o r)
INDOOR
on
CFM/To n
To rq u e
CFM
D9
S2
C10
+12V
R22
S 2
100% if necessary
50%
Efficiency
as required
3
minutes
OFF
OFF
39