Convertible air handlers 1-1/2 - 5 tonf or r-410a

Advertisement

18-GE02D2=4
Convertible Air Handlers
1=1/2- 5 Ton for R-410A
4TEP3F18A1000A
4TEP3F36A1000A
4TEP3F24A1000A
4TEP3F42A1000A
4TEP3F30A1000A
4TEP3F48A1000A
4TEP3F48B1000B
4TEP3F63A1000A
4TEP3F63B1000B
ALL
phases
of this
installation
must
comply
with
NATIONAL,
STATE
AND LOCAL
CODES
IMPORTANT
-- This Document
is customer
property
and is to remain
with this unit.
Please
return
to service
information
pack upon completion
of work.
A. GENERAL
iNFORMATiON
THIS iNFORMATiON iS FOR USE BY iNDiViDUALS
HAVING ADEQUATE BACKGROUNDS OF ELECTRICAL
AND MECHANICAL EXPERIENCE. ANY ATTEMPT TO
REPAIR A CENTRAL AiR CONDiTiONiNG PRODUCT
MAY RESULT iN PERSONAL iNJURY AND/OR PROP=
ERTY DAMAGE. THE MANUFACTURER OR SELLER
CANNOT BE RESPONSIBLE FOR THE INTERPRETA-
TION OF THiS iNFORMATiON, NOR CAN iT ASSUME
ANY LiABiLiTY iN CONNECTION WiTH iTS USE.
Contents
General information
...........
installation Limitations &
...........
Unit Installation
Upflow
Downflow
Horizontal Left
Horizontal Right
To prevent shortening its service life, the air handler
should not be used during the finishing phases of
construction. The low return air temperaturescan
lead
to the formation of condensate. Condensat_ ;i_;;;the
presence of chlorides a nd fluorides from pai; !i _ish,
stains, adhesives, cleaning
......
creates acorrosive
.........
deterioration of the cabinet _;_ int_ _al _p
;_ents.
These instructions
cover 811v_ i ;_ns in sys-
tems or provide for
Should
further
_formation
e _
_ed o} particular
problems
ar_
_
:are_
_
sufficiently
by this manual,
co
;t No
lo ::_ distributor
or the manufacturer
as
handler
nameplate.
Thes_:_r
Ha_lers
are shipped from the factory in the
upflow
horizontal
right configuration
and are fully
convertible
to downflow or horizontal
left. Refer to
Section B beginning
on page 3 for additional
information.
iNSPECTiON
Check carefully for any shipping
damage.
This must be
reported
to and claims made against
the transportation
company immediately.
Check to be sure all major
components
are in the unit. Any missing parts should
be reported
to your supplier
at once, and replaced
with
authorized
parts only.
Drain Piping
Eh
-- Power Wiring
Control
Wiring
Checkout
Procedure
Hook-up
Diagrams
Outline
Drawings
Cardboard packing material must be removed from
inside the blower assembly before starting the unit.
Failure to do so may cause indoor blower motor failure.
INSTALLATION
LIMITATIONS
& RECOMMENDATIONS
The general
location
of the air handler
is normally
selected
by the architect,
contractor
and/or
home
owner
for the most
effective
application
and satisfaction.
These
air handlers
are suitable
for installation
in a closet,
alcove or utility
room with free, non-ducted,
air return,
using
the area
space as a return
air plenum.
With ducted
supply
air, if the minimum
clearances
to combustible
materials
and service
access
are observed,
the above
installations
are suitable.