5-3 Extended Menu

5-3-1 Items in the Extended Menu

The extended menu contains the following items.
In the "Settings" column of the table, the factory
default settings are indicated by an enclosing box.
Item number Item name
101
SELECTION FOR
SEARCH DIAL ENABLE
102
MAXIMUM TAPE SPEED
(DNW-A30/A30P only)
104
AUDIO MUTING TIME
105
REFERENCE SYSTEM
ALARM
CAPSTAN LOCK
106
5-8
Chapter 5 Menu System
Menu items in the 100s, relating to the control panels
Settings
Select how the unit enters the search mode.
DIAL : Turning the search dial switches to search mode.
KEY: One of the JOG, SHUTTLE, and VAR buttons must be pressed to switch to
search mode.
Select the maximum tape speed in the search mode.
×35 (DNW-A30) / ×42 (DNW-A30P) : The maximum speed for rewind and fast
forward, and the maximum speed setting of the search dial in shuttle mode is
35 times normal (DNW-A30) or 42 times normal (DNW-A30P).
×35/24 (DNW-A30) / ×42/24 (DNW-A30P): The maximum speed for rewind and
fast forward is 35 times normal (DNW-A30) or 42 times normal (DNW-A30P),
and the maximum speed setting of the search dial in shuttle mode is 24 times
normal.
×24: The maximum speed for rewind and fast forward, and the maximum speed
setting of the search dial in shuttle mode is 24 times normal.
Note
When using a digital cassette, regardless of this setting the maximum speed is 50
times normal.
Select the length of time for which audio muting occurs when the unit switches to
playback either from stopped or from still playback in the search mode (for
Betacam compatible playback only).
OFF : Set the audio muting time to zero (i.e. no muting).
0.1S ... 1.0S: Set the audio muting time from 0.1 seconds to 1.0 second, in 0.1-
second increments.
Select whether or not to display a warning when the video/audio reference signal
selected by the OUT REF switch on the subsidiary control panel, is not supplied
or is out of phase with the input video signal.
OFF: No warning.
ON : Flash the STOP button as a warning.
Select the capstan servo lock mode.
SW : The capstan servo lock mode is determined by the CAPSTAN LOCK switch
on the subsidiary control panel.
2F: The capstan servo locks every two fields regardless of the setting of the
CAPSTAN LOCK switch on the subsidiary control panel.
4F: The capstan servo locks every four fields regardless of the setting of the
CAPSTAN LOCK switch on the subsidiary control panel.