Sony DNW-30P Operation Manual page 47

Digital videocassette player
Hide thumbs Also See for DNW-30P:
Table of Contents

Advertisement

Item number
Item name
726
H BLANKING WIDTH
Item number Item name
802
DIGITAL AUDIO MUTE IN
SHUTTLE MODE
805
AUDIO MONITOR
OUTPUT MIXING
806
LEVEL METER SCALE
807
AUDIO OUTPUT PHASE
808
INTERNAL AUDIO
SIGNAL GENERATOR
809
AUDIO LEVEL METER
DIMMER CONTROL
Menu items in the 700s, relating to video control (Continued)
Settings
Select the horizontal blanking width of a video output signal.
NARROW : Digital blanking (narrow)
WIDE: Analog blanking (wide)
When analog blanking is selected, the horizontal blanking width complies with
RS170A, and normally the blanking is widened and the image becomes narrower.
It is recommended to select NARROW at the editing stage, then later, for
broadcast transmission to select WIDE, to output a signal conforming to the
standard.
Menu items in the 800s, relating to audio control
Settings
Set the digital audio muting conditions during shuttle playback. However, the
digital audio signal is muted irrespective of this setting when the tape speed is 24
times the normal speed or more.
OFF : Not muted.
CUEUP: Muted during cue-up or preroll operations.
FULL: Muted in shuttle mode.
Select the audio mixing method used for digital audio signals and Betacam
playback analog audio signals supplied to the MONITOR OUTPUT connector.
ADD: Simple addition.
RMS : Root-mean-square.
AVE: Simple average.
Select the mode in which digital audio levels are displayed.
PEAK0 : Displays the audio level as negative values with the maximum level set
to 0 dB.
REF0: Displays the audio level as positive and negative values with the reference
level set to 0 dB.
The CUE channel (digital Betacam analog audio) level is always displayed in
REF0 mode.
Select the output timing of a digital audio playback signal (SIF and AES/EBU
only). The reference position corresponds to a setting of 80H; when the setting
is less than 80H, the output timing is advanced, and when it is higher than 80H,
the output timing is delayed. (80H, 128 samples = approx. 2.7 ms, and 80H, 1
sample=approx. 20 µs)
0 ... 80 ... FF : Setting in this range.
Select the operation of the internal audio test signal generator.
OFF : No operation.
SILNC: Silent signal.
1KHZ: At 1 kHz, –20 dB FS sine wave is supplied to all audio input channels.
For settings other than OFF:
When no cassette is inserted in the unit, a test signal from the internal audio test
signal generator is input to all audio channels.
Set the brightness of the audio level meters.
0 ... 7: Set in this range. 0 is the brightest, and 7 the dimmest.
5-15
Chapter 5 Menu System

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dnw-30Dnw-a30Dnw-a30p

Table of Contents