Canon CR-1 MARK II Operation Manual page 131

Retinal imaging control software nm
Hide thumbs Also See for CR-1 MARK II:
Table of Contents

Advertisement

module id message id
Entered Model No. is not numeric or the value is
7
out of the range between 1 and 99.
Length for storage path for the study file is too
8
long. Shorten to less than 80 bytes.
Character '\' or control character cannot be used for
22
Accession No.
Character '\' or control character cannot be used for
23
Patient ID.
Character '\,' line feed code, or control character
24
cannot be used for Study Description.
Character '\', '^' or control code cannot be used for
25
Patient Name.
Multi-byte character cannot be used for Patient
26
Name.
Character '\', '^' or control code cannot be used for
29
Referring Physician.
10049
Out-of-Range Birth Date (A date earlier than 1869
39
or later than tomorrow is entered.)
40
Entered date is invalid for Birth Date.
A character/characters for Patient ID is/are not
41
supported by Specific Character Set.
A character/characters for Accession No. is/are not
42
supported by Specific Character Set.
A character/characters for Patient Name is/are not
43
supported by Specific Character Set.
Entered characters are not acceptable because they
44
do not match Specific Character Set.
A character/characters for Referring Physician is/
45
are not supported by Specific Character Set.
A character/characters for Study Description is/are
46
not supported by Specific Character Set.
52
Folder for study file is not set.
Length value for Accession No. of Input
2
Restrictions is not numeric or is not in the range of
1 to 16.
3
Character set for Accession No. is not specified.
Length value for Patient ID of Input Restriction is
6
not numeric or is not in the range of 1 to 64.
7
Character set for Patient ID is not specified.
10
Character set for Patient Name is not specified.
Character set for Study Description is not
10050
11
specified.
13
Starting Value is not numeric or out of range.
Total length of Starting Value and Accession No.
15
Header String exceeds the limit.
16
Counter value is set to 1.
Header String for Patient ID exceeds the
17
maximum length.
8. Before calling the service technician (Warning)
Message
-123-
Detail
Set the model number to a number from 1 to 99.
Set the length of the storage path to less than 80
bytes.
The study information in the study file (ccrhis.his) is
invalid. Delete the backslash (\) and any control
characters.
The study information in the study file (ccrhis.his) is
invalid. Delete the backslash (\), line feed code, and
any control characters.
The study information in the study file (ccrhis.his) is
invalid. Delete the backslash (\) and any control
characters.
The study information in the study file (ccrhis.his) is
invalid. Delete the multi byte characters.
The study information in the study file (ccrhis.his) is
invalid. Delete the backslash (\) and any control
characters.
The study information in the study file (ccrhis.his) is
invalid. Input the correct birth date.
The study information in the study file (ccrhis.his) is
invalid. Input using the specific character set.
The study information in the study file (ccrhis.his) is
invalid. Delete the single-byte Japanese kana
characters.
The study information in the study file (ccrhis.his) is
invalid. Input using the specific character set.
Specify the folder to save the study file (ccrhis.his).
Set the length limitation of the Accession No. to 16
digits or less.
Specify the input character type.
Set the length limitation of the Patient ID to 64
characters or less.
Specify the input character type.
Set the Starting Value using a number in the correct
range.
Adjust the length of the header string to set the total
length of the starting value and header string within
the length limitation.
Check the value of the counter.
Set the length of the Header string within the length
limitation.
Continued on the following page >>

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents